80a three phase voltage current protective energy meter voltage protector

Model
WTS238-7 VAP
Nature of the Manufacturer
Manufacturer
Product Category
Breaker & Contactor
Place of Origin
City, Province
Overview
80a three phase voltage current protective energy meter voltage protector
Product Details

80a three phase voltage current protective energy meter  
voltage protector


Products Description


  WST238-7 VAP type multi-function Protective Device is designed to measure three phase four wire 

AC active energy / reactive and used in overvoltage protection, under voltage protection and over-

current protection. In case of over-voltage fault, under-voltage fault or over-current fault in line, this 

product can instantly power off the load to prevent electrical equipment from being burnt. The over-

voltage, under-voltage and over-current values of this product can all be set up by yourself and can 

be adjusted on the basis of local practical condition .It is a long use-life product with the advantage 

of high stability , high over load capability , low power loss and wide working voltage range.


Functioning


■LCD display with backlight , can display total active energy (kWh), total reactive energy (kvarh),

  three phase real time current(A), voltage(V), active power (KW),reactive power (kvar) .power

  factor ,frequency

■LCD display kWh (6 digital+2 decimal), Bi-directional total active energy measurement reverse

  active energy measure in the total active energy

■Product self-design has function of lighting protection

■Overvoltage protection, under voltage protection and over-current protection and lose phase

  protection can select auto-Reclosing mode or manual--Reclosing mode

■In case of over-voltage fault, under-voltage fault or over current fault, lose phase in any phase line,

  the product can power off the line and can automatically restore connecting the line over a time

  delay after voltage of the lien is recovered to normal condition.

■In case of transient over voltage in line, the product can protect the equipment from false operation.

■In case that the line subjects to unstable voltage or sudden power-off and power-on due to

  loosened connection and other fault, the product will disconnect the line.

■When fault voltage of the line reaches the peak, the product itself will not be damaged.

■Lose neutral line protection

■Lose phase protection ,and there have phase led indication on meter

■Unbalance voltage protection , if the voltage unbalance value exceed the setting value between

  any 2 phase of three phase .the device will cut off the load

■Over-current protection mode

■It can setting delay time for delay switch on / switch off function

■Interval active energy measure , it can resettable in any time after push button last 5s

■Last 5 times protection event records

■Diversified design for the protection , you can closed t any one of overvoltage protection, under

  voltage protection and over-current protection in any time

■35mm din rail installation , bottom type wire connection


Technical Parameters


Input working voltage
160~300V phase-N
Overvoltage protection value
85-300V ( default 270V) phase-N
Under voltage protection value
85-300V ( default 170V) phase-N
Over current protection value
1-80A
Rated frequency
50/60Hz
Delay in switch on after power off
5-255s ( default 5s) phase-N
Voltage circuit power consumption
≤1W each phase
Current circuit power consumption
<1VA each phase
Active energy display range
0~999999.99kWh
Voltage/current/active power accurate
+0.5%
Active energy accurate
+1% (IEC62053-21)
Operating temperature
-25℃ ~+70℃
Storage temperature
-40℃ ~+80℃
Relative humidity
≤85%
Altitude
≤2500m
Electromagnetic Environment
E2
Mechanical life
≥100000 cycles


Wiring diagram