WSW85M400A12VDCor24VDCMillerWelderWSW200A/12VWeldingContactorMainfeatures200AContactswitchingcapabilityIthasasetofmagneticholdingcontactorformCoilpowerconsumption:9~15WMin~Max
WSW85M 400A 12V DC or 24V DC Miller Welder WSW200A/12V Welding Contactor
Main features
· 200A Contact switching capability
· It has a set of magnetic holding contactor form
· Coil power consumption :9~15W Min~Max.
· Application Scope:Telecommunication and communication equipment,wind energy,
photovoltaic, uninterruptible power supply and other electronic control systems.
· Product features:Compact structure, high breaking capacity,low power consumption,
long service life and easy installation
· Technical specifications:GB/T14048.4-2020
· Product compliance: ROHS
· Product certification: CE
Application

Interpretation of product model

Example:WSW85M/48.A5;Indicates that the rated current of a group of magnetic holding contactors under DC-1 load is 200A,
and the coil voltage is DC48V
Performance parameter
| Model | |
| Contact form | A set of magnetic retention |
| Contact material | |
| Contact load | |
| Contact pressure drop | |
| Insulation resistance | |
| Dielectric Strength | 1000VAC 50 HZ/60 HZ (1 minute) Leakage current less than 1mA |
| Pulse width | |
| Pull in time | |
| Release time | |
| Pull-in voltage (DC V) | |
| Release voltage (DC V) | |
| Operating ambient temperature | |
| Storage temperature | |
| Relative humidity | |
| Mechanical life | |
| Auxiliary switch | |
| Minimum load of auxiliary contact | |
| Class of pollution | |
| Working system | Continuous working system |
| Vibration | (10~200)Hz acceleration ≤3.5g |
| To attack | (60) Times / minute acceleration 6g |
Coil parameters
| | | Coil operating voltage(V) | | | | |
| WSW-85M/□.A5 | | 0.85US~1.1US | 20~80% | 20~80% | | |
| | | |
| | | |
| | | |
Outline installation dimensions and circuit schematic diagram

Matters needing attention
1.When installing the contactor, the tightening torque of the main circuit wiring screw nut is 8~10N.m;
Control circuit wiring screw nut tightening torque 1~1.5N.m.
2.The driving circuit power of the product coil must be greater than or equal to the product coil power,
Otherwise the cutting capacity of the product will be reduced.
3.The voltage continuously applied to the coil shall not exceed the maximum allowable voltage.
Otherwise, the abnormal heating of the coil will shorten the life of the insulation layer.
Packaging & Shipping


WSW85M 400A 12V DC or 24V DC Miller Welder WSW200A/12V Welding Contactor
Main features
· 200A Contact switching capability
· It has a set of magnetic holding contactor form
· Coil power consumption :9~15W Min~Max.
· Application Scope:Telecommunication and communication equipment,wind energy,
photovoltaic, uninterruptible power supply and other electronic control systems.
· Product features:Compact structure, high breaking capacity,low power consumption,
long service life and easy installation
· Technical specifications:GB/T14048.4-2020
· Product compliance: ROHS
· Product certification: CE
Application

Interpretation of product model

Example:WSW85M/48.A5;Indicates that the rated current of a group of magnetic holding contactors under DC-1 load is 200A,
and the coil voltage is DC48V
Performance parameter
| Model | |
| Contact form | A set of magnetic retention |
| Contact material | |
| Contact load | |
| Contact pressure drop | |
| Insulation resistance | |
| Dielectric Strength | 1000VAC 50 HZ/60 HZ (1 minute) Leakage current less than 1mA |
| Pulse width | |
| Pull in time | |
| Release time | |
| Pull-in voltage (DC V) | |
| Release voltage (DC V) | |
| Operating ambient temperature | |
| Storage temperature | |
| Relative humidity | |
| Mechanical life | |
| Auxiliary switch | |
| Minimum load of auxiliary contact | |
| Class of pollution | |
| Working system | Continuous working system |
| Vibration | (10~200)Hz acceleration ≤3.5g |
| To attack | (60) Times / minute acceleration 6g |
Coil parameters
| | | Coil operating voltage(V) | | | | |
| WSW-85M/□.A5 | | 0.85US~1.1US | 20~80% | 20~80% | | |
| | | |
| | | |
| | | |
Outline installation dimensions and circuit schematic diagram

Matters needing attention
1.When installing the contactor, the tightening torque of the main circuit wiring screw nut is 8~10N.m;
Control circuit wiring screw nut tightening torque 1~1.5N.m.
2.The driving circuit power of the product coil must be greater than or equal to the product coil power,
Otherwise the cutting capacity of the product will be reduced.
3.The voltage continuously applied to the coil shall not exceed the maximum allowable voltage.
Otherwise, the abnormal heating of the coil will shorten the life of the insulation layer.
Packaging & Shipping





Our Services
1. Prompt reply: Any inquiry or questions would be replied within 24 hours.
2. Quality Product: Manufacture company, each of the products is tested and calibrated.
3. Hospitality: Offer smiling service and your visiting is highly welcomed
4. Fast delivery: delivery time is within 3-7 days usually, other occasion depends on the order qty.



Our Services
1. Prompt reply: Any inquiry or questions would be replied within 24 hours.
2. Quality Product: Manufacture company, each of the products is tested and calibrated.
3. Hospitality: Offer smiling service and your visiting is highly welcomed
4. Fast delivery: delivery time is within 3-7 days usually, other occasion depends on the order qty.