1. Application CM1 series moulded case circuit breaker is one of products developed and manufactured by adopting international advanced technology. It is supplied with rated insulating voltage 550 and 800V and used for circuit of AC 50/60Hz, rated operating voltage AC 400V (or below), rated operating current up to 1600A for infrequent changing over and starting of the motors.The products conforms to IEC60947-2 standard.
2. Main Technical Specification
Type
Rated current (A)
Polenum-ber
Ratedinsui-atingvolt-age(V)
Rated operat-ingvolt-age(V)
Arcing- over distance (mm)
Ultimate short circuit breaking capacity (KA)
Servies short circuit breaking capacity (KA)
Operation perform- ance
Utiliza-tioncat-egory
Load
Unload
CM1-63L
(6),10 16,20 25 ,32 40,50 63
3, 4
500V
400V
0
25
18
1500
8500
A
CM1-63M
0
50
35
CM1-100L
(10),16 20,25 32,40 50,63 80,100
800V
0(≤50)
35
22
CM1-100M
0(≤50)
50
35
CM1-100H
0(≤50)
85
50
1000
7000
CM1-225L
100,125 160,180 200,225
≤50
35
22
CM1-225M
≤50
50
35
CM1-225H
≤50
85
50
1000
4000
CM1-400L
225,250 315,350 400
≤50
50
35
CM1-400M
≤100
65
42
CM1-630L
400,500 630
≤100
50
35
CM1-630M
≤100
65
42
CM1-630H
≤100
100
65
CM1-800M
630,700 800
3
≤100
75
50
CM1-800H
≤100
100
65
CM1-1250M
1000,1250
≤100
100
65
CM1-1250H
≤100
125
75
CM1-1600M
1600
≤100
150
80
Note: 6A without thermal protection The N-pole of four-poles breaker is sited at the right side of the product has four types: Type A: Without current trip-lease on N pole which making all the time, not closing and opening with the other three poles. Type B: Without current trip-release on N pole which closing and opening with the other poles. Type C: With current trip-release which closing and opening with the other three poles. Type D: With current trip-release which making all the time not closing and opening with the other three poles.
1. Application CM1 series moulded case circuit breaker is one of products developed and manufactured by adopting international advanced technology. It is supplied with rated insulating voltage 550 and 800V and used for circuit of AC 50/60Hz, rated operating voltage AC 400V (or below), rated operating current up to 1600A for infrequent changing over and starting of the motors.The products conforms to IEC60947-2 standard.
2. Main Technical Specification
Type
Rated current (A)
Polenum-ber
Ratedinsui-atingvolt-age(V)
Rated operat-ingvolt-age(V)
Arcing- over distance (mm)
Ultimate short circuit breaking capacity (KA)
Servies short circuit breaking capacity (KA)
Operation perform- ance
Utiliza-tioncat-egory
Load
Unload
CM1-63L
(6),10 16,20 25 ,32 40,50 63
3, 4
500V
400V
0
25
18
1500
8500
A
CM1-63M
0
50
35
CM1-100L
(10),16 20,25 32,40 50,63 80,100
800V
0(≤50)
35
22
CM1-100M
0(≤50)
50
35
CM1-100H
0(≤50)
85
50
1000
7000
CM1-225L
100,125 160,180 200,225
≤50
35
22
CM1-225M
≤50
50
35
CM1-225H
≤50
85
50
1000
4000
CM1-400L
225,250 315,350 400
≤50
50
35
CM1-400M
≤100
65
42
CM1-630L
400,500 630
≤100
50
35
CM1-630M
≤100
65
42
CM1-630H
≤100
100
65
CM1-800M
630,700 800
3
≤100
75
50
CM1-800H
≤100
100
65
CM1-1250M
1000,1250
≤100
100
65
CM1-1250H
≤100
125
75
CM1-1600M
1600
≤100
150
80
Note: 6A without thermal protection The N-pole of four-poles breaker is sited at the right side of the product has four types: Type A: Without current trip-lease on N pole which making all the time, not closing and opening with the other three poles. Type B: Without current trip-release on N pole which closing and opening with the other poles. Type C: With current trip-release which closing and opening with the other three poles. Type D: With current trip-release which making all the time not closing and opening with the other three poles.