LW8-40.5 SF6 Circuit breaker high voltage 35KV Transmission line Tank type 35kV high voltage vacu...

Model
Nature of the Manufacturer
Manufacturer
Product Category
Air Circuit Breaker
Place of Origin
City, Province
Overview
1.connect spring operating structure or electromagnetic actuator structure, 2.remote controlelectric points, closing, o local manual energy storage, manual, closing. Design and performance in line 3. SF6 Gas insulate
Product Details

LW8-40.5 SF6 Circuit breaker high voltage 35KV Transmission line Tank type 35kV high voltage vacuum circuit breaker

Silicone rubber violet: heat resistance, cold resistance, dielectric resistance, ozone resistance and atmospheric aging resistance
Copper metal material: the product is made of red copper metal material and stainless steel, which is not rusty, easy to rust and good contact
Stainless steel shell: truly maintenance free performance

ItemDescriptionunitData
1Rated voltageKV35
2ceiling voltageKV40.5
3Rated insulation levelLightning impulse withstand voltage (full wave peak)KV185/215()
Power frequency withstand voltage (1 minute)KV95/118()
4Rated currentA1600/20001600/2000/2500/3150
5Mechanical lifeTimes5000500030002000
6Mechanical life rated pressure of sulfur hexafluoride gas (gauge pressure at 20 ºC)Mpa0.350.380.450.5
7Locking pressure (gauge pressure at 20 ºC)Mpa0.30.330.40.45
8Minimum operating ambient temperatureºC-40-30
9Rated short-circuit breaking currentkA202531.540
10Rated short-circuit making current (peak)kA506380100
11Rated short-time withstand current (thermal stability current)kA202531.540
12Cumulative breaking times under rated out of step breaking current and rated short-circuitkA506380100
13breaking currentkA56.3810
14Closing time (under rated operating voltage)Times15151010
15Opening time (under rated operating voltage)s<0.1
16Rated operating sequences<0.06
17Rated opening and closing current of single capacitor bank Open-0.3s-close open-180s-close open
18Rated short circuit durationA400
19Annual air leakage rates4
20Moisture content of sulfur hexafluoride gas (at 20 ºC)%/year<1
21Rated operating voltage of ct14 spring operating mechanismPpm(v/v)<150
22Voltage of closing coil and opening coilvAC 220/380V DC 48 110V 220V
23Energy storage motor voltagevAC 220V ,DC220V
24Sulfur hexafluoride gas weightkg8
25Weight of circuit breaker (including operating mechanism)kg1400

LW8-40.5KV AIR CIRCUIT BREAKER