40.5KVPad Mounted Transformer Economic type high voltage switchgear cable distribution network lo...

Model
Nature of the Manufacturer
Manufacturer
Product Category
Air Circuit Breaker
Place of Origin
City, Province
Overview
Small size ,pad mounted transformer 1.incoming outgoing in one panel 2.load breaker switch replace vs1 vacuum circuit breaker
Product Details

Products Advantage:

  • 1.Compact structure, small volume, is only about the 1/3 – 1/5 of the same capacity european type substation, which greatly reduce the occupation area
    2.Fully sealed and fully insulated structure, no need insulation distance .
    3.The wiring connection of high voltage can be used in loop feed and radial feed. Power supply method is flexible and reliable.
    4.Excellent performance; low consumption, low noise, low temperature –rising, high overload, anti short-circuit, high impact resistance, reliable protection of personal safety
    5.Meet all kinds of low voltage outgoing requirements .
    6.Cable head has 200A elbow plug & 630A “T” shape fixed type. All insulated Zinc Oxide lightning arrester can be configured. 200A cable head can be plugged in with load, also can be acted as isolation switch.

Products Structure:


    1. Plug-in fuse
    2. Pressure gauge
    3. Pressure relief valve
    4. Oil level indicator
    5. Oil temperature gauge
    6. Load break switch
    7. High voltage cable connector
    8. Off load tap changer
    9. Grounding points
    10. Drain valve
    11. Low voltage switchgear


    Technical Parameter

      Item

      Unit

      Parameter

      High Voltage Unit

      Rated frequency

      Hz

      50/60

      Rated Voltage

      kV

      11

      13.8、15

      20、22

      30,33,36

      Max service voltage

      kV

      12

      17.5

      24

      40.5

      Rated current

      A

      400、630、1250、1600、2000、
      2500

      transformer current

      A

      400~2500

      1min power frequency withstand voltage to earth and phase
      to phase /Fracture

      kV

      42/48

      48/55

      55/65

      85/95

      BIL: to earth and phase to phase
      /Fracture

      kV

      75/85

      90/105

      125/150

      170/185

      Rated short circuit breaking current

      kA

      25、31.5、40

      Transformer Unit

      Rated Voltage

      kV

      11、13.8、15、20、22、30、33、36

      Rated Capacity

      kVA

      160~1250

      Tap ranging

      %

      +/-2x2.5%、+/-5%

      Vector Group

      Yyn0、Dyn11

      Impedance

      %

      4、4.5、6、8

      Low Voltage Unit

      Rated Voltage

      V

      220、400、690、800

      Main circuit rated current

      A

      400~2500

      Branch current

      A

      63~1250

      Enclosure

      Protection Level

      HV Room:IP44
      Transformer Room:IP44
      LV Room:IP44

      Noise level

      dB

      ≤50

      Structure Characteristics

      • The enclosure structure is made of channel steel and angle steel which has higher mechanical strength. The enclosure is made of aluminum alloy plate ,its face is even and smooth . The product is elegant appearance with better anti-erosion. The foundation of substation is higher 300- 600 mm than ground. All the doors are opened outward with angle more than 90°. The substation has handle, dark latch and dormant lock with waterproof anti-blocking and anti rust.

      • The body is whole enclosed against theft to ensure the working under a common air temperature, the temperature of all electrical devices do not be more than the max. allowed temperature of itself. It is equipped with enough natural vents and insulation measures.The prefabricated transformer substation is equipped with special grounding conductor .On the grounding conductor ,there has terminals to connect with ground net .Its number is more than two pieces and has obvious grounding mark. The ground terminal is copper bolt with diameter more than 12mm. The grounding conductor adopts copper strip which current density can not be more than 200A/mm, the cross section is more than 30mm , to ensure that the flow through the maximum short-circuit current does not overheat or affect the safety of the surrounding objects. Dynamic and thermal steady current of the special grounding conductor should be equipped with grounding methods of H.V. power distribution devices.

      Transformer Performance Parameter


        Pad mounted transformer -Transformer parameter

        No

        Capacity

        Rated voltage

        Tap
        Range
        (%)

        No load current (%)

        Losses(W)

        Impedance
        (%)

        kVA

        HV
        (kV)

        LV
        (kV)

        S9

        S11

        No load

        Load

        S9

        S11

        S9

        S11

        1

        30

        6.6
        7.2
        11
        13.815
        20
        22
        30
        33
        36

        0.4
        (0.69)

        +/-5
        ±2*
        2.5%

        2.2

        2.0

        130

        600

        4

        2

        50

        2.0

        1.8

        170

        870

        3

        63

        1.9

        1.5

        200

        1040

        4

        80

        1.7

        1.2

        250

        1250

        5

        100

        1.6

        1.1

        290

        1500

        6

        125

        1.5

        1.0

        340

        270

        1800

        7

        160

        1.4

        1.0

        400

        310

        2200

        8

        200

        1.4

        0.8

        480

        375

        2600

        9

        250

        1.2

        0.8

        560

        400

        3050

        3000

        10

        315

        1.1

        0.7

        670

        475

        3650

        3600

        11

        400

        1.0

        0.7

        800

        570

        4300

        4200

        12

        500

        1.0

        0.6

        960

        680

        5100

        5000

        13

        630

        0.9

        0.6

        1200

        800

        6200

        6000

        4.5%

        14

        800

        0.8

        0.6

        1400

        1120

        7500

        7400

        15

        1000

        0.7

        0.5

        1700

        1320

        10300

        9860

        16

        1250

        0.6

        0.5

        1950

        1360

        12800

        12000

        17

        1600

        0.6

        0.5

        2400

        1840

        14500

        14000


        Note:

        a. According to customer requirements, the high voltage tap range of transformer can be designed to be + 2 * 2.5%.
        b. According to customer requirements, the transformer low voltage can be designed as 0.69kV

        Load Break Switch Parameter

          Rated Current (A)

          Rated Voltage (kV)

          BIL
          (kV)

          Power frequecny
          Withstand voltage
          (1min.kV)

          Rated short - time withstand current
          (kA/S)

          Short circuit making current
          (kA)

          Rated withstand current (peak)
          (kA)

          Load
          Operation
          times
          (kA)

          Mechanical
          Operation
          times

          315

          11

          75

          42

          12.5/2

          31.5

          31.5

          100

          2000

          630

          11

          75

          42

          16/4

          40

          40

          100

          3000