Welcome Customer !

Membership

WENZHOU JUNKE ELECTRIC CO., LTD.
Free Member ·1YRS
WenZhou,ZheJiang
Manufacturer

Main Products: Transfer Switch (Combination Switch)|Miniature Circuit Breaker|Other Moisture Meters

Xwboo>Products

WENZHOU JUNKE ELECTRIC CO., LTD.Free·1YRS

  • E-mail

    energymeter@yiagroup.com

  • Phone

    008657762893983

  • Address

    Yishan Industry Zone Liushi Yueqing Zhejaing China

Contact Now

Single phase 3 wire Cl200 30/200A Ansi Socket Meter FM 2S 3W

Model
Nature of the Manufacturer
Manufacturer
Product Category
Place of Origin
City, Province
Overview
Single Phase Socket Type kwh Meter ANSI Class 0.5 Accuracy Arrow indicator for energy direction flowVisible LED Instantaneous value measurement and display(kw.V A)r Contains total active energy register and active energy registerAvailable Met
Product Details
Main Functionalitiesr
Single Phase Socket Type kwh Meter
ANSI Class 0.5 Accuracy
Arrow indicator for energy direction flow
Visible LED
Instantaneous value measurement and display(kw.V A)r
Contains total active energy register and active energy register
Available Meter Forms
FM 1S . 2W . CLASS 100
FM 1S . 2W . CLASS 200
FM 2S . 3W . CLASS 100
FM 2S . 3W . CLASS 200
Anti-tamper Features ( optional )
Missing Neutral - Detect and record energy consumption even with missing neutral on input side , load side , or both Bypassed - Detect and record actual energy consumption even when one line is bypassed
oppositive -detect and oppositive record energy flowas normal energy consumption
ValAccuracyue ValCA0.5 ue
Voltage
Reference voltage
Operating voltage range

240V
70%-120%Un (168V – 288V)
Current
Test amperes (TA)
Current classes
Starting current

15A ,30A
100A ,200A
50mA for CL100, 100mA for CL200
Frequency60HZ
Power Consumption
Power consumption in voltage circuit (active)
Power consumption in voltage circuit (apparent)
Power consumption in current circuit

≤2 W
≤10 VA
≤1 VA
Meter Constant 1000 imp/kWh
Wiring System 2 wire line to neutral (240V – 0V)
2 wire line to line no neutral (120V – 120V) (center tap on distribution
transformer’s secondary should not be connected to ground)
3 wire line to line with neutral (120V – 0V – 120V)
LED Visible IR LED test pulse for energy
Communication Interface
Optical communication
Infrared communication
RF (868 MHz)
IEC62056-21 encryption
IRDA
IEC
Temperature
Operation range
Limit range for storage and transport
-25℃~65℃
-40℃~70℃
HumidityUp to 95% non-condensing
Housing
Protection degree
Meter cover
IP65 (Outdoor Installation)
Opaque polycarbonate(PC) + glass fiber with a transparent window
Dimension 175mm x 175mm x 130mm
Software Supply ,and install computer