CX-FS-FE40 piston flow switch

Model
Nature of the Manufacturer
Other
Product Category
Flow Switch
Place of Origin
City, Province
Overview
Illustrate: CX-FS-FE40 piston flow switch used for gas and liquid . Suitable for industrial automation / mechanical equipment/compressed air industry /refrigeration and air conditioning .
Product Details

CX-FS-FE40 series Piston flow switch


Application 
CX-FS-FE40 type used for gas and liquid . Suitable for industrial automation / mechanical equipment/compressed air industry /refrigeration and air conditioning .
Feature 
1,On-line installation  2,Mechanical type flow switch  3, Suitable for gas and liquid  4,Firm plastic, aluminum or stainless steel housing  5,Small pressure loss  6,Good repeatability and stain resistance  7,The mechanical part isolate from the electric part totally , it is economical type and suit for small flow range.  8, 3 times piston journey respond to original FE20 , which makes sure the high accuracy .  9, With switch setting scale ,so the used does not need to set in field . 10, LED display the switch state (option: double switch value output) .
 
Technical data
△Set range:         See parameter list
△Accuracy:         ±5%FS
△Delay:            Depend on the switch point , min. point 0.6L/Min
△Switch set scale:    Calibrate it under the horizontal installation for water medium (20 C) . Installation position : The medium and the temperature will effect the switch value .
△LED display:       Display the switch state , if the LED is directly current supply . 
It will no LED display for AC supply .
△Connection:        M12 
△Output:            Reed switch, capacity 24VDC / 250VAC ,100mA
△Pressure proof:      10bar(plastic),  50bar(aluminum),  100bar( stainless steel)
△Average pressure loss: 0.3bar( at 25L/min)
△Medium temperature:  Max.90 Celsius degree
△Protective class:      IP65
△CX-FS-FE40…GP material: Housing: POM plastic,
                     Piston: POM plastic
                     Reed switch: stainless steel 
Seal: NBR
△CX-FS-FE40…GA material : Housing: anode alumina
                      Piston: POM plastic
                      Reed switch: stainless steel
                      Seal: NBR
 
Parameter list

TypePressure
Bar
Max.flow rate
L/min(water)
Adjustable range
L/min(water)
G
mm
L
mm
H
mm
B
mm
X
mm
Weight
Kg
FE40-008…L(X)00850400.6(0.1)..8(7)G1/4933630120.22(0.53)
FE40-010…L(X)00850400.6(0.1)..8(7)G3/8933630150.20(0.51)
FE40-015…L(X)00850400.6(0.1)..8(7)G1/2933630150.18(0.48)
FE40-020…L(X)00850400.6(0.1)..8(7)G3/41053635150.23(0.65)
FE40-025…L(X)00850400.6(0.1)..8(7)G11053640150.32(0.82)
FE40-008…L(X)01550401(0.5)…15(13)G1/4933630120.22(0.53)
FE40-010…L(X)01550401(0.5)…15(13)G3/8933630150.20(0.51)
FE40-015…L(X)01550401(0.5)…15(13)G1/2933630150.18(0.48)
FE40-020…L(X)01550401(0.5)…15(13)G3/41053635150.23(0.65)
FE40-025…L(X)01550401(0.5)…15(13)G11053640150.32(0.82)
FE40-015…L(X)02550402(0.8)…25(25)G1/2933630150.18(0.48)
FE40-020…L(X)02550402(0.8)…25(25)G3/41053635150.23(0.65)
FE40-025…L(X)02550402(0.8)…25(25)G11053640150.32(0.82)
FE40-020…L(K)07050(100)10027(21)…70(66)G3/41053635150.23(0.65)
FE40-025…L(K)07050(100)10027(21)…70(66)G11053640150.32(0.82)
 
 
            CXFE40-008… /CXFE40-010...
 
 
              CXFE40-015...
 
 
               CXFE40-020… /CXFE40-025...
 

Note : 
1, The parameter in bracket is reset point, the parameter outside the bracket is action point .If the lower limit alarm (the monitoring flow rate is too small) ,at the time reference the reset parameter . If the upper limit alarm (the monitoring flow rate is too big) , then reference the action parameter .
2, Under vertically installing on horizontal pipe , then test to get the above parameter for 20 Celsius degree water..
 
Installation                       wiring
 
 
Note : The installation position will effect the switch value .
 
 
Type selection sheet 

CXFE40-008GDL015M1 
CXFE40-       CXFE40 series piston type flow switch
 008      G1/4
 010      G3/8
 015      G1/2
 020      G3/4
 025      G1
  G     Female screw
   D    DC 24V±20%DC
   J    AC 230V±15%AC
    S   Plastic housing
    L   Anode alumina housing
    X   Stainless steel housing
     008  Set range :0.6…8L/min
     015  Set range :1…15L/min
     025  Set range :2…25L/min
     070  Set range :27…70L/min
      M M12
      Z Direct cable
       11 switch point output
       22 witches point output
1. It should mention the medium direction , medium ,pipe diameter and the expected set value ,when placing the order . Then we can set it before leaving factory .
2,If the medium is viscous medium , please notice the viscosity , temperature and medium .
3. If the medium is gas , please notice the pressure( meter pressure /absolute pressure) ,temperature and medium .
 
Optional accessory
ZL04-PU02MZdescription
ZL04-    M124-core connector
SL04-    M12 
 PU   PUR
  02  2m
  05  5m
  10  10m
   M Female plug
    ZDirect type
    WBend type
 
 
Similar Product Recommend