CX-LSM-1609A laboratory sodium meter

Model
Nature of the Manufacturer
Other
Product Category
Lab Instrument
Place of Origin
City, Province
Overview
Illustrate:It can be widely used for continuous monitoring of sodium ions of the solutions in thermal power plants, chemical fertilizer, metallurgy, environmental protection, pharmaceutical industry, biochemical industry, foodstuff and running water.
Product Details

CX-LSM-1609A Laboratory Sodium Meter


Brief Introduction
1.CX-LSM-1609Ais made based on the improvement of the previous pointer scale display, knobs, switches and non-intelligence design.
2.It is equipped with the dedicated laboratory PPB sodium ion measurement electrode and the reference electrode, with the static measurement performance in the beaker greatly improved, compared with the traditional sodium meters.
 
Main Features
1.Double-row nixie tube: To display μg/L, pNa/mV and temperature simultaneously.
2.Computer-based: To adopt high-performance CPU chip, high-precision AD conversion technology and 8usMTtechnology to complete multi-parameter measurement and temperature compensation, with high precision and good repeatability
3.High reliability: Single board structure, touch button, no switch knob
4.Input impedance :> 1012Ω
5.High sensitivity: In the static water sample, it can detect 0.2ppb (8pNa)
6.Lasting stability: There is a very stable reading.
7.Waterproof and anti-erosion design
8.Network function: RS232 bi-directional communication, equipped with a printer or TLab8.0 communications and
data processing software.

Main Parameters

DisplayDouble-row nixie tubes display
Measuring range0.2 ug/L~23000mg/L,0.00 Pna~8.00 PNa.-1000~ +1000 mV. 0~99.9°C
Resolution0.1 ug/L; 0 .1 mV, 0.1°C
Repeatabilityreading ± 2.5%
Accuracy reading ± 2.5%, ±0 .2 mV, ±0.3°C
Continuous stability time>100 seconds
Detection lower limit0 .2 ug/L (8pNa)
Input impedance>1012Ω
Temperature compensation rangeautomatic/manual 0 ~ 99.9 °C
Response speed32 seconds (25°C) or 50 seconds (15°C)
Communication interfaceRS232 bi-directional communication
Power supplyAC 220V ± 22V, 50Hz ± 1Hz, external power supply
Power-down memory> 5 years
Calibration modeOne-point calibration, two-point calibration
Working conditionsambient temperature: 0-60°C;  relative humidity <≤90
Standard configuration:One secondary instrument; one power supply; one reference electrode, one measuring electrode, one temperature electrode; a set of electrode support, a set of standard buffer solution