Capacity range 5~20000KG S-beam design, both tension and compression High accuracy, water-proof, anti-corrosion Widely applied in the electronic truck scale, crane scale and hopper scale
·Building industry (weighing materials, power shovels)
·Agriculture (automatic feeders)
·Public sector (weighing garbage)
·Quality assurance
Introduction of Load Cell
Tension Compression load cell is ideal for use in static and quasi-static weighing tasks; for instance, for the gravimetric level measurement of suspended tanks as well as for conveyor, batching, and hybrid scales. It is available in seven maximum capacities, which range from 5 kg to 20000 kg, thus covering a very broad range, the product is widely used for various scale, industrial weighing system.
·Building industry (weighing materials, power shovels)
·Agriculture (automatic feeders)
·Public sector (weighing garbage)
·Quality assurance
Introduction of Load Cell
Tension Compression load cell is ideal for use in static and quasi-static weighing tasks; for instance, for the gravimetric level measurement of suspended tanks as well as for conveyor, batching, and hybrid scales. It is available in seven maximum capacities, which range from 5 kg to 20000 kg, thus covering a very broad range, the product is widely used for various scale, industrial weighing system.
Special features of Load Cell
·S-beam design,Both tension and compression force
·High precision
·Excellent dustproof
·High accuracy, water-proof, anti-corrosion
Load Cell electric specification
Power supply: 5~24VDC
Various optional output signal: 2.0mV/V, (if connect with amplifier, 4~20mA, 0~5V, 0~10V etc)
Input resistance: 380±10Ω
Output resistance: 350±3Ω
Insulation resistance: 2000MΩ
Load Cell construction
Alloy steel
Specifications
Technical data
Rated capacity
5 10 20 30 50 100 20000 KG
Output sensitivity
2.0±0.002 mV/V
Non-linearity
≤±0.02 %F.S.
Hystersis
≤±0.02 %F.S.
Repeatability
≤±0.02 %F.S.
Creep
±0.03 %F.S./30min
Temperature effect on output
±0.02 %F.S./10℃
Temperature effect on zero
±0.02 %F.S./10℃
Input resistance
380±10 Ω
Output resistance
350±3 Ω
Zero output
<±1 %F.S.
Insulation resistance
≥5000MΩ
Operating temperature range
-25~+70 ℃
Safe overload
150 %F.S
Ultimate overload
300 %F.S
Recommended excitation voltage(without amplifier)
5~12 Vdc
Maximum excitation voltage(without amplifier)
15 Vdc
Material
Alloy steel
IP protection
IP67
Load Cell electric specification
Power supply: 5~24VDC
Various optional output signal: 2.0mV/V, (if connect with amplifier, 4~20mA, 0~5V, 0~10V etc)