Welcome Customer !

Membership

Hebei Huanhai Import and Export Co., Ltd.
Free Member ·1YRS
BaoDing,HeBei
Manufacturer

Main Products: Other Test Chambers|Other Testing Machines

Xwboo>Products
Product Categories

Hebei Huanhai Import and Export Co., Ltd.Free·1YRS

  • E-mail

    sales02@electric-hz.com

  • Phone

    0086-312-6775522

  • Address

    Electicity Valley Tech Centre, No.3088 LeKai Street, Hi-tech Zone, Baoding, HeBei,China

Contact Now

HZKS-3RAutomatic open fla

Model
Nature of the Manufacturer
Manufacturer
Product Category
Place of Origin
City, Province
Overview
HZKS-3RAutomatic open fla
Product Details

I. Overview

ZKS-3R automatic open flash point ignition point tester is designed and manufactured in accordance with the requirements specified in the People's Republic of China standard GB/T3536ASTMD92 "Petroleum Products Flash point and ignition point determination (Cleveland open cup method) and GB/T267-1988, ASTMD92 Petroleum products flash point and ignition point determination (open method)

Model

HZKS-3R

Name

Automatic open flash point and ignition tester

Test Project

It can meet the requirement of petroleum, chemical, railway, aviation, electric power, commodity inspection and scientific research institutes for petroleum product testing.

Conform Standard

GB/T 3536, GB/T267-1988, ASTMD92

Technical characteristics

Unmarked keyboard, for predictable temperature, sample label, atmospheric pressure, test date and other parameters, with a prompt menu, guided input function

 

II. Instrument Characteristics

1. The instrument adopts color LCD large screen display, English interface, no identification keyboard, for predictable temperature, sample label, atmospheric pressure, test date and other parameters, with a prompt menu, guided input function.

2. Simulation tracking display temperature rise and experimental time function curve, with English error operation software prompt modification function, with test date, test time and other parameters prompt function

3. Automatically correct the influence of atmospheric pressure on the test and calculate the correction value

4. Differential detection, automatic correction of system deflection

5. Scan, detect, print data automatically completed, the test arm automatically rise and fall

6. Electronic ignition, forced air cooling

7. Automatic ignition without air source, improve the safety of the test

 

III. Main technical indicators and parameters

1. Imput power: AC220V±10%, 50Hz

2. Temperature measurement range: room temperature ~400°C

    Repeatability: flash point ≤150°C error ±3°C

Resolution: 0.1°C; Accuracy: 0.5%

3. Heating rate: comply with GB/T3536 standard

4. Ignition mode: electronic ignition, gas flame 3mm~4mm;

5. Ambient temperature :(10~40)°C

6. Relative temperature: ≤80%