Welcome Customer !

Membership

Anhui Zhimin Electrical Technology Co., Ltd.
Free Member ·1YRS
BangBu,AnHui
Manufacturer

Main Products: Load Cell|Indicator|Pressure Sensor

Xwboo>Products

Anhui Zhimin Electrical Technology Co., Ltd.Free·1YRS

  • E-mail

    info@zhiminsensor.com

  • Phone

  • Address

    No.712 Lao Shan Road, Bengbu, Anhui Province, China

Contact Now

3 axis force load cell sensor

Model
Nature of the Manufacturer
Manufacturer
Product Category
Multi axis force sensor
Place of Origin
City, Province
Overview
The ZM3DW 3 axis load cell utilizes independent wheatstone full bridge for Fx, Fy, Fz which provides mV/V output proportional to the applied force and requires no mathematical manipulation. Cusotmaztion can consist of load cells with client's outer dimension, mouting size, output signal etc. Used with Zhimin's data logger which can collect load cell's voltage signal and display force curve. Features: Capacity 50N-500kN 3 axis-Fx Fy Fz independent bridges Low crosstalk Compact size Optional features: 0......
Product Details

The ZM3DW load cell XYZ utilizes independent wheatstone full bridge for each axis which provides mV/V output proportional to the applied force and requires no mathematical manipulation. Typical applications for this type of transducer are for example force exertion control in robotics, automotive crash testing, industrial test benches, grinding force control, actuator operating force measurement,etc.


Dimensions in mm


PARAMETER

VALUE

UNIT

Material

Alloy steel


Capacity

50, 100, 200, 500, 1000, 2000, 5000

N

Sensitivity X-Axis

0.5-1.0

mV/V

Sensitivity Y-Axis

0.5-1.0

mV/V

Sensitivity Z-Axis

0.5-1.0

mV/V

Zero balance

1

±% of rated output

Input resistance X,Y-Axis

700±5

Ohms

Output resistance X,Y-Axis

700±5

Ohms

Input resistance Z-Axis

350±5

Ohms

Output resistance Z-Axis

350±5

Ohms

Insulation resistance

5000

Mega-Ohms

Accuracy

1

±% of rated output

Non linearity

0.2

±% of rated output

Hysteresis

0.05

±% of rated output

Temperature effect on min. dead load output

0.0026

±% of rated output/℃

Temperature effect on sensitivity

0.0015

±% of rated output/℃

Creep error (30 minutes)

0.03

±% of rated output

Crosstalk from X to Y

1

±% of rated output

Crosstalk from Y to X

1

±% of rated output

Crosstalk from Z to X/Y

1

±% of rated output

Crosstalk from X/Y to Z

5

% of R.C

Safe overload

150

% of R.C

Ultimate overload

300

Vdc

Excitation, recommended

10

Vdc

Compensated temperature range

-10 to +40

℃

Operating temperature range

-20 to +60

℃