E-mail
export@wedhb.com
- Phone
-
Address
Changjie North Road, Chagnsha City, Hunan Province, China
Membership
Help
Welldone Environmental Protection Equipment (Changsha) Co., Ltd.Free·1YRS
export@wedhb.com
Changjie North Road, Chagnsha City, Hunan Province, China
Clean Air Tower
Suitable for centralized treatment of welding fume, grinding and polishing dust, new material processing and other dust.
Product Introduction
Clean Air Tower is made of fan, motor,cartridge filter , and air supply/return port. With the structure of downward air supply & upper air return , and the continuous circulating purification method ,the machine is able to deal with difficulties in collecting smoke and dust which create a clean working environment .Generally,it solve following problems: 1. Unfixed welding and polishing stations 2. Frequent changes in smoke and dust points. The unique quick-loading method for cartridge filter and the mechanical lifting device of the ash bucket make maintenance easy and simple. The PLC automatic control system make the operation simple and reliable, the unique internal noise reduction treatment make the operating noise extremely low.

Features
Integrated structure design, compact and reasonable structure, small footprint.
The purification method of bottom air supply & upper return air cycle , and the air supply outlet can adjust the wind direction 。The equipment is divided into two parts, the upper air inlet tube can be split for delivery and assembled on site.The height dimension of the air inlet tube can be customized according to the actual situation.
The unique quick installation method of the cartridge filter, just rotate the handle gently, the cartridge filter will be separated automatically , which make the replacement and maintenance of the cartridge filter easily. The vertical installation structure lead to more thorough cleaning, and longer service life.
The unique mechanical lifting device of ash bucket makes it easy and quick to discharge ash, and with good sealing parameter, no dust leakage and trouble points. The cartridge filter is equipped with pressure difference detection, which can realize automatic dust removal according to the clogging of the cartridge filter, and can also be cleaned regularly.
Built-in PLC automatic control system, with touch screen, easy to operate and more unified with the entire equipment. No need for matching air ducts, flexible installation and simple installation process.
Technical Parameters
Model | WJT-6.0
|
Volume | 6000m3/h |
Power | 5.5kW
|
Filter Efficiency | 99.9% |
Filter specification | Φ324*1000mm |
Number of Filter | 4 |
Ash bucket volume | 40L |
Noise | <75dB(A) |
Compressed air | 0.4-0.6MPa |
Voltage/Phase/Frequency | 380V/3PH/50Hz |
Size(Length*thickness*Hight) | 1250*1195*4551mm |
Weight | 1500Kg |
Size

Installation Instruction
This machine is only suitable for equipment that uses 3-phase electricity. This operation must be
completed by a qualified electrician. The power socket is not included. Please install a suitable socket.
If you move the machine to a different outlet or use a new extension cable, you must check the rotate
direction of the fan. Check whether the power supply voltage is the same as the voltage on the product
nameplate before turn on the power supply. Check whether the compressed air pressure is ≥ 0.5MPa.
Operation Instruction
The control system of this product adapt programmable logic controller (PLC) as the control center, which realize the operation control of the equipment, the safety protection of the system,as well as the fault alarm and auxiliary functions .
Powered on and the touch screen lights up;
After the touch screen is normal, enter the "Run interface"
Click the "Start" button in the operation interface of the touch screen to start
Select the "Pressure difference cleaning" or "Timing cleaning" mode according to your needs
Click the stop button in the operation interface of the touch screen to stop ;
After the fan stops, the equipment enters the offline cleaning mode;
The cleaning mode of "Timing/Pressure difference" can be switched as requirement, and the once cleaning interval time can be adjusted. When the "Power Switch" remains " ON". After the fan stops, the dust removal function will continue to run for a certain period of time which could be adjusted.
Adjusted the interval time : Adjusted the Cleaning time:
Adjusted range:0-60sec Adjusted range:0-60sec
Default mode:30sec Default mode:30sec
Machine care and maintenance
Disconnect the power of the machine before starting any maintenance and repair work.
The regular maintenance interval must be determined by qualified operators based on local usage conditions and working frequency. Maintenance should be carried out after 1000 working hours, at least one time in every 6 months.
Check whether all the valves in the dust removal system are working properly, and clean the dust in the lower part of the filter room.
1. Empty the ash bucket
Empty the ash bucket when it is close to 70% of its capacity. Don't overfill the ash bucket. Overfilling the ash bucket will reduce the filtering performance, and when the ash bucket is taken out, the dust overflow will cause excessive cleaning work.
Note: Goggles, earmuffs, respiratory protection and gloves should be used when emptying the ash bucket.
Ash bucket emptying steps:
1. Disconnect the power of the machine.
2. Open the base access door and loosen the buckle
until the ash bucket falls to the ground.
3. Pull out the ash bucket and pour the dust in the
ash bucket into the recycling truck.
4. Push the ash bucket in and fasten the buckle to the top
of the ash bucket to ensure the tightness of the ash bucket.
5. Close the base access door tightly.
is not installed in place.

2.Check the compressed air filter pressure reducing valve
①. The filter pressure reducing valve is installed on the side of the equipment. It is
necessary to check whether there is water or oil in the filter pressure reducing valve.
If there is water, it means that the compressed air is not dry enough and there is a
danger of damaging the filter . Open the discharge port at the bottom of the filter
to drain the water off.
②. Check whether the pressure is set to 0.4-0.6MPa.
Note: There is filters inside the filter pressure reducing valve, it is suggested to
replace once a year.