0.6/1kV XLPE Insulation Service Drop Cable

Model
Nature of the Manufacturer
Manufacturer
Product Category
Service drop cable
Place of Origin
City, Province
Overview
0.6/1kV XLPE Insulation Service Drop Cable
Product Details

Application

Service Drop Cable(ABC CABLE) are mainly used for electric power tranmission, rebuiding of urban and forest regions. They can improves safety and reliance of electrified wire netting.

Type

Service Drop Cable(ABC CABLE) covers mainly three types:

Duplex Service Drop

Triplex Service Drop

Quadruplex Service Drop

The cable can be produced whose construction is phase conductor with neutral bare conductor or phase conductor with insulated neutral conductor , etc. And we can still produce the cables according to the request of customers.

Detaild Introduction

3.1 Duplex Service Drop

Applications

To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75 maximum.

Construction

Concentic strand or cmpressed 1350-H19 conductor , polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy nertral messenger.

3.2 Triplex Service Drop
Applications

To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation .

Construction

Concentic strand or cmpressed 1350-H19 conductor , polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy nertral messenger.

3.3 Quadruplex Service Drop

Applications

Used to supply 3 phase power , usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made . To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.

Construction

Conductors are concentrically standed , compressed 1350-H19 aluminium . Insulated with either polyethylene or XLPE . Neutral messengers aer concentrically stranded 6210 AAAC , AAC or ACSR .

Standard: IEC, BS, DIN, NFC, ASTM, NFC, and so on

Other special characteristic: design and manufacture according to customer’s special