The Durable Quality Mechanical Variable Area Flow Meter works base on the differential pressure principle,the float inside will go up and down to give the area to maintain the differential pressure between the position before and after the float.The float go up and down and drive the indicator to show the flow rate.The durable quality mechanical variable area flow meter is totally mechanical type which is easy to install and maintenance,the flow meter do not need external power supply to work which will not be affe......
Product Details
Mechanical Variable Area Flow Meter
The Durable Quality Mechanical Variable Area Flow Meter works base on the differential pressure principle,the float inside will go up and down to give the area to maintain the differential pressure between the position before and after the float.The float go up and down and drive the indicator to show the flow rate.The durable quality mechanical variable area flow meter is totally mechanical type which is easy to install and maintenance,the flow meter do not need external power supply to work which will not be affected by the factor of power.
Measure Medium
Water,Oil,Compressed Air,Nitrogen
Flow range
Water 2.5 l/h to 200 m3/h
Air 0.07 to 4500m3/h (201.013bar)
Flow span
10:01
Accuracy
Standard accuracy: 1.5% High accuracy: 1.0%
Standard accuracy (PTFE-Liner): 2.5% High accuracy (PTFE-Liner): 1.5%
Connections
Flange connection
Standard: DIN2501DN15-DN200 )
Special: DIN2512DN15-DN200
ANSI1/2-8
The GB JIS users needs
Threaded fittings DIN11851SC40-SC80[1-1/2-3]
According to demands of users
Steam Jacket Connections
Internal threads 1/2
NPT
Flange connection DN15 PN40 DIN2501
According to demands of users
Max.Allow. pressure
250bar
Temperature range
Fluid temperature
-40 to+200Standard type
-20 to+125PTFE-Liner type
-40 to+400High temperature type
Ambient temperature
-40 to+70
Materials
SS304,SS304L,SS316,SS316L
PTFE-Liner
Hastelloy C
Ti
According to demands of users
Protection class
IP67
Supply power
12-28V DCtwo-wire systembattery power
Ex-Design
ExdIIBT6
Precautions for installation of Mechanical Variable Area Flow Meter
In order to make the metal tube rotameter work normally and achieve a certain measurement accuracy, the following points should be paid attention to when installing the flow meter:
1. The metal tube rotameter must be installed vertically on the vibration free pipeline. The fluid flows through the flowmeter from bottom to top, and the perpendicularity is better than 2 °, and the horizontal angle is better than 2 ° when installed horizontally;
2. In order to facilitate the maintenance and replacement of flowmeter and cleaning of measuring pipeline, the metal tube rotameter installed on the process pipeline shall be equipped with bypass pipeline and bypass valve;
3. The metal tube rotameter shall have a straight pipe section of more than 5 times the pipe diameter at the inlet and a straight pipe section of 250mm at the outlet;
4. When it is used for gas measurement, the pipeline pressure shall not be less than 5 times of the pressure loss of the flowmeter, so as to make the float work stably;