Our boiler steam vortex flowmeter has a built-in temperature and pressure sensor. By obtaining temperature and pressure signals and built-in steam density comparison table, the total consumption and instantaneous flow of boiler steam are directly displayed in the billing unit. It plays an important role in steam cost accounting and saving in many industries.
Product Details
Durable Boiler Steam Vortex Flowmeter
Our boiler steam vortex flowmeter has a built-in temperature and pressure sensor. By obtaining temperature and pressure signals and built-in steam density comparison table, the total consumption and instantaneous flow of boiler steam are directly displayed in the billing unit. It plays an important role in steam cost accounting and saving in many industries.
Product Name
Vortex flow meter
Nominal diameter
DN15-DN300,DN150~DN2000 can use the insertion vortex flowmeter, and the big caliber is more suitable for insertion type.
Scope of application
Gases (air, oxygen, nitrogen, gas, natural gas, chemical gas, etc.), liquids (water, high temperature water, oil, food liquid, chemical liquid, etc.), steam (saturated steam, superheated steam)
Medium temperature
-40°C~250°C,-40°C~350°C,-40°C~400°C
Nominal pressure
≤1.6MPa ≤2.5MPa ≤4MPa Special pressure can be customized
Accuracy level
Liquid 0.5%
Gas, steam 1.5%
insertion type 2.5%
Medium velocity range
Liquid:0.6~6m/s,Gas:5~60m/s,steam:5~70m/s.
Output Signal
Voltage pulse,4-20mA Current output,HART Agreement,RS485.
Converter power supply
Voltage pulse output:+12VDC, 4~20mA Current output:+24VDC; Live LCD display:3.6V1 No. 1 lithium battery power supply, the service life is more than 2 years
Ambient temperature
Voltage pulse output:-30°C~+65°C, 4~20mA Current output:-10°C~+55°C;
Live LCD display:-25°C~+55°C
Body material
1Cr 18Ni 9Ti (Other materials according agreement to supply)
Precautions for installation of boiler steam vortex flowmeter
When installing the connecting pipe of the boiler steam vortex flowmeter, the horizontal deviation of the horizontally installed sensor pipe is required to be within 5 ° and the perpendicularity deviation of the vertically installed sensor pipe is also required to be within 5 °. The bypass pipe and stop valve must be installed in the place where continuous operation cannot be stopped, and the bypass pipe shall be free of leakage during measurement.
Pay attention to the opening and closing sequence of boiler steam vortex flowmeter. For the boiler steam vortex flowmeter without bypass pipe, first open the upstream valve of the flowmeter with medium opening, and then slowly open the upstream valve. After operating at a small flow rate for a period of time, fully open the upstream valve, and then open the large downstream valve to adjust to the required normal flow. When the bypass pipe is installed, fully open the bypass valve first, open the upstream valve with a medium opening, slowly open the downstream valve, and close the opening of the bypass valve, so that the instrument can operate for a certain period of time with a small flow. Then the upstream valve is fully opened, the bypass valve is fully closed, and the downstream valve opening is finally adjusted to the required flow rate.
When the steam vortex flowmeter of the boiler is put into use for the first time, a section of short pipe shall be connected at the position where it is connected to the flowmeter for pipeline cleaning and pigging, and then it shall be connected to the flowmeter after confirming that the pipeline is cleaned. If there is such measuring object, such as replacing oil products or shutting down the product pipeline, the pipeline cleaning and pigging work shall be carried out on schedule. The flow direction, flow rate, pressure and temperature of the fluid used for line cleaning and pigging shall be in accordance with the specification of the flowmeter, otherwise the accuracy of the flowmeter will be affected or even the flowmeter will be damaged.