Biogas gas production is not only an important parameter to measure the economic benefits of biogas production equipment, but also an important factor to affect whether the fermentation process is safe and reliable.Our sensitive biogas vortex flowmeter has sensitive sensing elements, which can maintain accuracy under low pressure conditions.At the same time, the sensitive biogas vortex flowmeter is made of stainless steel, which can deal with the corrosion caused by the moisture in biogas.
Product Details
Sensitive Biogas Vortex Flowmeter
Biogas gas production is not only an important parameter to measure the economic benefits of biogas production equipment, but also an important factor to affect whether the fermentation process is safe and reliable.Our sensitive biogas vortex flowmeter has sensitive sensing elements, which can maintain accuracy under low pressure conditions.At the same time, the sensitive biogas vortex flowmeter is made of stainless steel, which can deal with the corrosion caused by the moisture in biogas.
Product Name
Vortex flow meter
Nominal diameter
DN15-DN300,DN150~DN2000 can use the insertion vortex flowmeter, and the big caliber is more suitable for insertion type.
Scope of application
Gases (air, oxygen, nitrogen, gas, natural gas, chemical gas, etc.), liquids (water, high temperature water, oil, food liquid, chemical liquid, etc.), steam (saturated steam, superheated steam)
Medium temperature
-40°C~250°C,-40°C~350°C,-40°C~400°C
Nominal pressure
≤1.6MPa ≤2.5MPa ≤4MPa Special pressure can be customized
Accuracy level
Liquid 0.5%
Gas, steam 1.5%
insertion type 2.5%
Medium velocity range
Liquid:0.6~6m/s,Gas:5~60m/s,steam:5~70m/s.
Output Signal
Voltage pulse,4-20mA Current output,HART Agreement,RS485.
Converter power supply
Voltage pulse output:+12VDC, 4~20mA Current output:+24VDC; Live LCD display:3.6V1 No. 1 lithium battery power supply, the service life is more than 2 years
Ambient temperature
Voltage pulse output:-30°C~+65°C, 4~20mA Current output:-10°C~+55°C;
Live LCD display:-25°C~+55°C
Body material
1Cr 18Ni 9Ti (Other materials according agreement to supply)
Precautions for measuring biogas with vortex flowmeter
Generally, the flow of biogas pipeline is small, and it is generally measured by reducing the diameter.
We can choose flange card type and flange type,When selecting the type, we must know the minimum flow, common flow and maximum flow of biogas. Most of the biogas measurement sites do not have power supply. We can choose battery powered sensitive biogas vortex flowmeter. If the user needs to lead the display of the meter to the room, the integrated sensitive biogas vortex flowmeter can be used. The output signal can be led to the flow integrator installed in the room through the cable. The sensitive biogas vortex flowmeter can display the instantaneous flow and cumulative flow of biogas.
When the sensitive biogas vortex flowmeter is used to measure the biogas installation, if the valve is installed near the upstream of the installation point, and the valve is constantly opened and closed, the service life of the sensor will be greatly affected, and it is very easy to cause permanent damage to the sensor. The sensor should be avoided to be installed on the pipeline with a very long shelf space as far as possible. After a long time, the sensor sagging is abnormal It is easy to cause seal leakage between sensor and flange. If it has to be installed, pipe fastening device must be set at 2D of upstream and downstream of sensor.In order to ensure complete function, the flow pattern at the entrance shall be undisturbed. The length of the upstream straight section shall be approximately 15 times the flowmeter diameter (d) and the downstream straight section shall be approximately 5 times the flowmeter diameter (d).