The use of liquid nitrogen is more and more extensive, the application of liquid nitrogen has covered a lot of people's lives, and brought us a lot of benefits. Liquid nitrogen is mainly used for freezing treatment in industrial production at the beginning of use, and now more and more aspects begin to use liquid nitrogen for freezing and cooling. The low temperature liquid nitrogen variable area flowmeter is used to continuously measure the volume flow of liquid and gas in the closed pipeline. It has a solid and r......
Product Details
Low Temperature Variable Area Flowmeter for Liquid Nitrogen
The use of liquid nitrogen is more and more extensive, the application of liquid nitrogen has covered a lot of people's lives, and brought us a lot of benefits. Liquid nitrogen is mainly used for freezing treatment in industrial production at the beginning of use, and now more and more aspects begin to use liquid nitrogen for freezing and cooling. The low temperature liquid nitrogen variable area flowmeter is used to continuously measure the volume flow of liquid and gas in the closed pipeline. It has a solid and reliable structure. It can be used to measure the flow under the conditions of high pressure and ultra-low temperature, and can adapt to the flow measurement in various occasions.
Measure Medium
Water,Oil,Compressed Air,Nitrogen
Flow range
Water 2.5 l/h to 200 m3/h
Air 0.07 to 4500m3/h (201.013bar)
Flow span
10:01
Accuracy
Standard accuracy: 1.5% High accuracy: 1.0%
Standard accuracy (PTFE-Liner): 2.5% High accuracy (PTFE-Liner): 1.5%
Connections
Flange connection
Standard: DIN2501DN15-DN200 )
Special: DIN2512DN15-DN200
ANSI1/2-8
The GB JIS users needs
Threaded fittings DIN11851SC40-SC80[1-1/2-3]
According to demands of users
Steam Jacket Connections
Internal threads 1/2
NPT
Flange connection DN15 PN40 DIN2501
According to demands of users
Max.Allow. pressure
250bar
Temperature range
Fluid temperature
-40 to+200Standard type
-20 to+125PTFE-Liner type
-40 to+400High temperature type
Ambient temperature
-40 to+70
Materials
SS304,SS304L,SS316,SS316L
PTFE-Liner
Hastelloy C
Ti
According to demands of users
Protection class
IP67
Supply power
12-28V DCtwo-wire systembattery power
Ex-Design
ExdIIBT6
The Causes the measurement error of Low Temperature Variable Area Flowmeter
1. Installation does not meet the requirements
Generally, the glass rotameter is installed vertically, and the inclination angle of the flowmeter shall not exceed 20 degrees during installation
There shall be no ferromagnetic objects in the space of 100mm around the rotameter. The installation position shall be far away from the valve reducer, pump outlet, process pipeline turning, etc. The requirement of 250mm straight pipe section after the first 5D shall be maintained.
2. The density of liquid medium changes greatly
Before the calibration of the instrument, the medium is converted to the density given by the user and converted to the flow of water in the calibration state for calibration. Therefore, if the density of the medium changes greatly, it will cause great errors in the measurement. The solution can bring the changed medium density into the formula, convert it into error correction coefficient, and then change the flow rate measured by the flowmeter multiplied by the coefficient into the real flow rate.
3: Long term use and pipeline vibration
Many factors make the moving parts of rotameter, such as sensing magnet, pointer, counterweight and rotating magnet, loose, resulting in large errors. Solution: first push the pointer by hand to verify. First, press the pointer at the RP position to see whether the output is 4mA and the flow display is 0%. Then verify according to the scale in turn. If any discrepancy is found, the parts can be adjusted. Generally, professionals are required to adjust, otherwise the position will be lost, and it is necessary to return to the manufacturer for correction.
Low Temperature Variable Area Flowmeter for Liquid Nitrogen