Chilled Water Electromagnetic Flow Meter For Boiler

Model
Nature of the Manufacturer
Manufacturer
Product Category
Electromagnetic Flow Meter
Place of Origin
City, Province
Overview
Application of electromagnetic flowmeter in the measurement of chilled water flow: electromagnetic flowmeter has obvious advantages in the measurement of chilled water flow. For example: no pressure loss, high precision, good stability. Electromagnetic flowmeter is characterized by no movable parts, high reliability, good sealing performance, and can also be used in tap water and underground water system.
Product Details

chilled water electromagnetic flow meter for boiler


Application of electromagnetic flowmeter in the measurement of chilled water flow: electromagnetic flowmeter has obvious advantages in the measurement of chilled water flow. For example: no pressure loss, high precision, good stability. Electromagnetic flowmeter is characterized by no movable parts, high reliability, good sealing performance, and can also be used in tap water and underground water system.

chilled water electromagnetic flow meter for boiler

chilled water electromagnetic flow meter for boiler (2)





Measure Medium

Water,Sewage,Acid,Alkali,Slurry,Milk

Nominal diameter

15-500mm

Degree of accuracy

±0.5%R

Medium conductivity

≥5uS/cm,Actual conductivity≥30uS/cm

Nominal pressure

1.0MPa

1.6MPa

2.5MPa

4.0MPa

DN15-DN500

DN15-DN500

DN15-DN500

DN15-DN50

Highest medium temperature

Compact type

+80℃

Remote type

CR chloroprene rubber liner (CR)

+80℃

Polytetrafluoroethylene lining(F4)

+120℃

Politef lining(F46)

+120℃

Teflon(PFA)

+180℃

Fluorosilicone rubber(FVMQ)

+250℃

Output signal

4-20mA;Pulse/Frequency 2kHz(Default),5KHz(Max)

Supply voltage

110/220VAC(100-240VAC),50Hz/60Hz;24VDC ±10%

Communication

RS-485,Support standard Modbus-RTU protocol;GPRS

Electrode material

Stainless steel 316L,Hastelloy C,Hastelloy B,titanium, tantalum, platinum

Level of protection

Remote type

IP68,IP65

Compact type

IP65


Because of the characteristics of chilled water, some problems should be paid attention to in the use of chilled water electromagnetic flow meter for boiler.


First of all, the internal problem of electromagnetic flowmeter, pay attention to the negative pressure of memory. When the measuring medium has certain corrosiveness, we need to use polytetrafluoroethylene memory material. But the electromagnetic flowmeter made of tetrafluoroethylene can not bear negative pressure.

There are two ways to solve the problem:

First, using the memory with framework, the disadvantage is to increase the investment cost.

Second, the original vent valve is changed into a one-way valve (check valve). When there is a small negative pressure in the pipeline, the check valve will automatically open to draw air from the atmosphere, so as to ensure safety.

chilled water electromagnetic flow meter for boiler (3)