Anti Corrosive Sea Water Electromagnetic Flow Meter

Model
Nature of the Manufacturer
Manufacturer
Product Category
Electromagnetic Flow Meter
Place of Origin
City, Province
Overview
In general industrial sea water Flow meter, the measured medium velocity of sea water Flow meter should be 2~4m/s. Under special circumstances, the velocity should not be less than 0.2 m / s and not more than 8 m / s. If there are solid particles in the medium, the commonly used velocity should be less than 3 m / s to prevent the excessive friction between the lining and the electrode; for the viscous fluid, the velocity can be more than 2 m / s, and the larger velocity is helpful to automatically eliminate the eff......
Product Details

Anti Corrosive sea water electromagnetic flow meter


In general industrial sea water Flow meter, the measured medium velocity of sea water Flow meter should be 2~4m/s. Under special circumstances, the velocity should not be less than 0.2 m / s and not more than 8 m / s. If there are solid particles in the medium, the commonly used velocity should be less than 3 m / s to prevent the excessive friction between the lining and the electrode; for the viscous fluid, the velocity can be more than 2 m / s, and the larger velocity is helpful to automatically eliminate the effect of the adhesive attached to the electrode and improve the measurement accuracy.

Anti Corrosive sea water electromagnetic flow meter

Anti Corrosive sea water electromagnetic flow meter (2)




Measure Medium

Water,Sewage,Acid,Alkali,Slurry,Milk

Nominal diameter

15-500mm

Degree of accuracy

±0.5%R

Medium conductivity

≥5uS/cm,Actual conductivity≥30uS/cm

Nominal pressure

1.0MPa

1.6MPa

2.5MPa

4.0MPa

DN15-DN500

DN15-DN500

DN15-DN500

DN15-DN50

Highest medium temperature

Compact type

+80℃

Remote type

CR chloroprene rubber liner (CR)

+80℃

Polytetrafluoroethylene lining(F4)

+120℃

Politef lining(F46)

+120℃

Teflon(PFA)

+180℃

Fluorosilicone rubber(FVMQ)

+250℃

Output signal

4-20mA;Pulse/Frequency 2kHz(Default),5KHz(Max)

Supply voltage

110/220VAC(100-240VAC),50Hz/60Hz;24VDC ±10%

Communication

RS-485,Support standard Modbus-RTU protocol;GPRS

Electrode material

Stainless steel 316L,Hastelloy C,Hastelloy B,titanium, tantalum, platinum

Level of protection

Remote type

IP68,IP65

Compact type

IP65




Anti Corrosive sea water electromagnetic flow meter WIre Requirement


All wiring shall be carried out after the power supply is cut off.

Put the cable into and out of the wire sleeve according to the correct procedure: first loosen the compression nut of the wire sleeve and remove the plug plate. Put the compression nut and rubber ring on the cable sleeve in turn, and then put the cable through the outlet sleeve. After wiring, straighten out the cable, and tighten the compression nut to make the rubber ring tightly press the cable.

When stripping the cable, pay attention not to damage the insulation layer that should be kept. For flow signal core wire, as long as it can be wired, try to peel off the shielding layer as little as possible. For stt3200 cable, after the inner shield leakage wire of two coaxial cables is twisted, the insulating sleeve shall be put on and then connected to SGND end. The black semiconductor layer shall be cut off from the root to avoid affecting other wiring.

Anti Corrosive sea water electromagnetic flow meter (3)

Anti Corrosive sea water electromagnetic flow meter (4)

Anti Corrosive sea water electromagnetic flow meter (5)

Explosion Proof Electromagnetic Flow Meter_07

Anti Corrosive sea water electromagnetic flow meter