QST-201 is used to measure inquid level from 2 to 200m.4~20mA,0~5V or 0~10v signal output can be selected.
Product Details
4-20mA 0-10V Liquid Level Pressure Transmitter
Product Introduction:
QST-201 series liquid level sensors are consisting of well-sealed immerging oil-filled liquid level transducers and special circuit for manometers. Have characteristics of high precision, good stability, long life and easy to fix. Adopt special sealed configuration, so with good capability of anti-leakage.
According the relation between pressure, density and liquid level, the liquid level transducers measure the liquid pressure which in direct ratio with depth of liquid, then via amplificatory circuit, the measured pressure is transferred to standard 4~20mA current signal(or standard voltage signal).
Feature:
◆Range:0~0.6 mH2O....0~200 mH2O
◆Sealed structure, IP68.
◆Accuracy: 0.1% FS, 0.25% FS (standard), 0.5% FS
◆There is two kinds of connector to be chosen: intracavity or flush membrane type
◆Integrated construction, without external adjustment.
Dimensions: (unit: mm)
Electrical connection:
Technical Specifications:
Measuring media
Liquid which are compatible to 316L stainless steel
Measuring range
mH2O
0~0.6,0~1,0~2,0~5,0~10,0~20,0~30,
0~50,0~100,0~150,0~200
Overload pressure
%FS
150
Signal output
transmitter, mA (2 wires)
4~20
transmitter, Vdc (3 wires)
0~5, 0~10
Power supply
Vdc
12~36(Model 24)
Static accuracy
%FS
0.1, 0.25(standard), 0.5
Zero adjustment
%FS
≤±0.25
Span adjustment
%FS
≤±0.25
Long-term stability
%FS/year
<±0.5
Response time
ms
<2
Storage temp.
ºC
-40~+100
Operation temp.
ºC
0~+80
Compensated temp.
ºC
0~+50
Temp. coefficient of ZERO
%FS/10ºC
0.2
Temp. coefficient of SPAN
%FS/10ºC
0.2
Insulation resistance
M Ω
≥500 @ 100 Vdc
Load resistance
current output, Ohm
250~1100
voltage output, Ohm
>5000
Environmental protection
IP rating
IP 68
pressure memberane material
316L SS
Material for housing
304 SS
Electrical connection
connector/cable
4-core,Ф7.6 mm shielded cable with vent pipe which is mechanically strong enough for deep submersible liquid level measurements