QP-86D is used to measure differential pressure.The signal output can be analog or digital output to select.
Product Details
Production Introduction:
Model:QP-86D differential pressure sensor
Dimensions :( unit: mm)
Span:
Range code
Range
Measure span
MIN
MAX
4
0.374KPa
37.4KPa
-37.4~37.4KPa
5
1.868KPa
186.8KPa
-186.8~186.8KPa
6
6.9KPa
690KPa
-690~609KPa
7
20.68KPa
2068KPa
-690~609KPa
Output:
Analog output: two wire 4~20mADC
Digital output: two wire 4~20mADC and variable digital signal in accordance with HART AGREEMENT.
Power: supply voltage 12.5~45VDC
Limit load: Max load resistor Rmax in loop decided by the supply voltage, see the below drawing. HART AGREEMENY require the load resistor not less than 250 Ω, not more than 600Ω
Communication distance: Max. 1.5km, multi-address communication can connect 15 smart transmitters max.
Static pressure and one side overload: 3.45Kpa(Absolute) 31.2MPa(Gauge)
Relative humidity:5 ~98%RH
Startup time: less than 5 sec.
Capability change: less than 4px3
Damp adjust: 0.20~25sec.
Malfunction alarming: If appear malfunction, automatism diagnose function will out 3.9 or 21.0mA
Protection: To avoid the datas are modified random, can utilize
Software or protect switch lock the memory data
Reference condition: zero is the lower limit and not offset, temperature 25℃, Atmospheric pressure, 24VDC power, silicon oil, diaphragm 316L, data adjust range the same as the up and lower limit of the range
Accuracy: ±0.1%, adjust range≥0.1URL
±[0.05+(0.005URL/span)]%, adjust range 0.025URL~0.1UPL
±[0.01+(0.006URL/span)]%, adjust range 0.01URL~0.025URLNote: accuracy have include the influence of linearlity, hysteresis and repeatability