Test capacity:1.5kVA-100kVATest voltage:50kV-500kVwithstand voltage time:≤5minInput voltage:220V/380V can be customizableTest object:Electrical products such as generators, insulators, transformers, HV switches, cables, bus bars, etc.
Product Details
Product description
Oil-immersed HV test transformer(AC/DC Hipot Test Set) is one advanced model in our company. This series of products are with small volume, light weight, compact structure, functional, strong commonality and convenient use, etc., Especially suitable for power system, industrial and mining enterprises, scientific research departments and all kinds of pressure electric equipment, electric components, insulation material or DC power frequency dielectric strength under high-voltage test. It’s essential for high-voltage test equipment.
Product nickname: ac dielectric test set, ac high voltage test equipment, hipot test machine , hv test set.
Oil-filled testing transformer advantage
1.Small size, light weight and compact structure, no leakage, maintenance free;
2.Oil-filled, good arc extinguishing effect.
3.Cooling fast after using.
4.Simple wiring, easy to use;
5.Reliable Insulation, beautiful appearance;
6.Over voltage protection function.
7.Long life-time using, maintenance cost is very low.
Oil-immersed HV test transformer paramer
Model *
Input
Output
Primary
Secondary
Size(mm)
Weight(kg)
3/50
AC200V
50kV
15A
60mA
320×240×620
40
5/50
25A
100mA
360×255×650
54
10/50
50A
200mA
410×285×750
72
15/50
AC400V
37.5A
300mA
440×290×760
93
20/50
50A
400mA
450×300×770
110
30/50
75A
600mA
480×320×800
180
50/50
125A
1000mA
550×350×840
244
5/100
AC200V
100kV
25A
50mA
460×350×1100
95
10/100
50A
100mA
490×350×1120
116
15/100
AC400V
37.5A
150mA
510×380×1180
160
20/100
50A
200mA
530×400×1200
182
30/100
75A
300mA
560×430×1250
205
50/100
125A
500mA
580×480×1350
225
15/150
150kV
37.5A
100mA
630×500×1650
235
20/150
50A
133mA
640×510×1680
240
30/150
75A
200mA
650×540×1710
255
50/150
125A
333mA
660×550×1750
285
20/200
200kV
50A
100mA
740×670×2100
300
30/200
75A
150mA
750×680×2200
350
50/200
125A
250mA
800×700×2250
420
Different specifications can be customized.
Different combinations
1. Oil-filled testing transformer with manual /automatic box(below 10kvA)
2. Oil-immersed test transformer with manual/electric/ automatic desk(above 10kvA)
Features for hv test transformer AOTU console
● Voltage, current, time, status information and prompt information and other data are displayed on a 10-inch large-screen LCD, with clear and intuitive readings;
● All Chinese interface, simple and clear operation, can be adapted to a variety of applications;
● Touch operation, all functions can be preset in advance, which improves the safety and reliability of the product;
● Status reminder function, all Chinese guided operation;
● Alarm function, closing alarm, 5 seconds buzzer alarm prompt; abnormal voltage signal collection, buzzer alarm;
● Emergency stop function, under automatic control, this function can realize the emergency stop of boosting or depressing at any point;
● Automatic timing function. In automatic control, when the voltage automatically rises to the set value, the device automatically starts timing, and when the timing expires, the device automatically drops the voltage and automatically returns to zero;
● Manual control mode, this mode is similar to the traditional electric boost/decrease mode, the up/down is controlled by the touch key, the device automatically judges the upper/lower limit, there is over-voltage and over-current protection;
● Using a combination of hardware and software anti-interference technology, stable performance and strong anti-interference.
Factory price AC DC Hipot Test Set | ac hipot tester Classification:
There are four kinds of high voltage testing transformer according to the medium points:
1. Oil-immersed high voltage transformer test: large capacity, cheap, convenient maintenance, mainstream products.
2. Inflatable HV test transformer : interrupter resistance, and the corona sound is small, not affected by the climate change ratio, has a long service life, has excellent arc extinguishing performance, and does not require maintenance.
3. Dry typehigh voltage testing transformer: light weight, light volume, can run backward,Easy to carry and can be transported by air.
4.insulating cylinder high voltage testing transformer: Using epoxy cast barrel shell, full insulation treatment, improve the insulation strength, high output voltage, the highest voltage level of a single device can reach 750KV.
After-sale service
1.First-use responsibility system
After the product is delivered, the technician can guide the operation at site if the client requires, and be responsible for the first use of each part
2.One year warranty
All products warranty is 1year, life-time maintenance .
During the warranty period, if any defects or damaged because of product’s quality, maintenance or replacement can be provided with free charge in order to let our client’s satisfied !
3.Troubleshooting
If the troubleshooting is not difficult, and client can handle with it by themselves, we can offer the call-on line guide within 1 hour!
If the troubleshooting is difficult to handle with for client, we can promise that the best solution can be provided within 24 hours!
Capacity selection of HV test transformer
The formula for determining the capacity Pn of the nominal power frequency test transformer: Pn=KVn2ωCt×10-9
Where: Pn——nominal power frequency test transformer capacity (KVA)
Vn——The effective value of the rated output high voltage of the power frequency test transformer (KV)
K-safety factor. K≥1, when the nominal voltage Vn≥1MV, K=2, when the nominal voltage is lower, the value of K can be higher.
Ct——The electric capacity of the tested product (PF)
ω——Angular frequency, ω=2πf, f——The frequency of the test power supply
The capacitance Ct of the equipment under test can be measured by an AC bridge. Ct varies greatly, depending on the type of equipment. Typical data are as follows:
Simple rod or suspension insulator, dozens of microfarads
Simple grading casing 100~1000pF
Voltage transformer 200~500pF
Power transformer<1000kVA ~1000pF
>1000kVA 1000~10000pF
High-voltage power cable and oil-impregnated paper insulation 250~300PF/m
Gas insulation ~60pF/m
Enclosed substation, SF6 gas insulation 100~10000pF
For different test voltages Vn, choose different (appropriate) safety factors K. The K values selected for different Vn are listed below for reference
Vn=50~100KV K=4
Vn=150~300KV K=3
Vn>300KV K=2
FAQ
1.Is it all right to make customer's own brand name?
Yes, if the quantity is big,we can accept the OEM.
2.Are you a manufactuer or trading company?
We are manufacturer.
3.Can you do the design for us?
Sure,we can design according to your test’s requirement.
4.Packaging & Shipping:
Packing: All shall be with the exported packing standard, with foam inside, strong woodencase packing.
Shipping: it is according to client’s requirements.
5.What is your terms of delivery?
50%deposit, the rest should be paid before delivery.
6.What's the MOQ for your production?
MOQ: 1 pcs
7.When can I get the price?
Within 6 hours.
8.If we have some other product requirements that your page don't include, can you help to supply?
Sure,any issues regarding the product’s details and after-sale service ,we will support in time!