DC HV generator is a technology product of new era, suitable for DC HV test and Dc leakage current test on zinc oxide arrester, magnetic blow-out arrester, power cable, generator, transformer, and switch in electric power department, scientific research unit, railway station, power plant, chemical plant, etc.
Product Details
Introduction
DC HV generator is a technology product of new era, suitable for DC HV test and Dc leakage current test on zinc oxide arrester, magnetic blow-out arrester, power cable, generator, transformer, and switch in electric power department, scientific research unit, railway station, power plant, chemical plant, etc.,
Hot tags: DC hipot tester, DC generator, DC test machine,DC high voltage test equipment, DC leakage current test set.
DC generator technical performance specification and working methods
●DC Hipot tester which takes technique of APWM, enhancing degree of linearity of PWM and ripple factor is less than 0.5%, Improve instrument accuracy.
●Adopting AI technology screen to set over voltage protection and over current protection.
●Bring great convenience to measurement of zinc oxide arrester with the added function of high-accuracy 75%VDC-1mA; accuracy ≤0.5%.
●Add timer function under any voltage and any current, with total timing T1 and Segmented timing T2, it have Calendar and time function.
Technical parameter
Specification
60/2/3
60/5
120/2/3/5
200/2/3
300/2/5
Technical Parameter
Output voltage((kV)
60
60
120
200
300
Output current (mA)
2/3
5
2/3/5
2/3
2/5
Output power (W)
120/180
400
240/360/600
400/600
600/1500
Charging current(mA)
3/4.5
5
3/4.5/6.5
3/4.5
3/7.5
Controller Case weight (kg)
10.1
13
13
13.1
13.1
Dimension of multi-voltage tube (mm)
Φ 90
Φ 110
Φ 90
Φ 110
Φ 110
× 380
× 530
× 470
× 910
× 1200
Height of multi-voltage tube (kg)
2.3
4
3.2
8.0
10
Voltage measuring accuracy
1.0%(full scale)± 1character, max resolution 0.1%kV
Current measuring accuracy
1.0%(full scale)± 1character, max resolution 0.1%uA
Over voltage rectify accuracy
≤ 1.0%
0.75 switch over accuracy
≤ 0.5%
Ripple factor
≤ 0.5%
Work manner
Intermittent service; 30min of rated load; 1.1 times of rated voltage use: 10min
Temperature
-10℃-50℃
Relative humidity
When at 25C, no more than 85%(no condensation)
Altitude
Below 1500m
Capacitance load
The capacitance of test object is no limit
Construction feature
Electric insulation multivoltage tube
Air insulation,no leakage
More specifications can be customized .
DC High Voltage Tester Wiring real picture
Product description
1.What about leading time for production ?
Usually , it depends on our production situation and the required model’s specification . Usually lead time is within 7 working days after deposit,customized model should be negotiated again!
2.When can I get the price ?
The quotation can be provided within 6hours . If you are very urgent, pls info@cablehipot.com, or call .
3.What is your terms of delivery ?
We accept EXW, FOB, CFR, CIF, DDU, DDP etc . You can choose the most convenient and cost effective terms for you .
4.How much is the shipping cost and logistic time ?
This is depend on the size and weight of your product, and the method of shipping ( by sea/ by ari/ by Express) and your designated port . Kindly afford us above information to check shipping cost and lostic time for you .
5.Can you provide the product calibration certificate?
Yes, we can issue our factory calibration certificate.
If you require the third-party calibration certificate, it also can be made,just if through the third party, it will be charged!