Rated voltage: 60kV/120kV/200kV/300kV(Can be customized)Leakage current:2mA/3mA/5mA(Can be customized) Ripple factor:With AIPWM technology, Ripple factor ≤0.5 %Test object:zinc oxide arresters, magnetic blowing arresters, power cables, generators, transformers, circuit breakers and other equipments
Product Details
Introduction
High voltage DC generator provides the most dependable, portable DC high voltage sources for checking the quality of zinco xide arrester, magnetic blow-out arrester, power cable, generator, transformer, and switchgear. It is widely applied in electric power department, scientific research unit, railway station, power plant, chemical plant, etc. For the DC hipot tester, it has two functions: For the DC high voltage test and DC leakage current test.
Hot tags: DC dielectric test set, DC generator, DC hipot tester, DC high voltage tester,DC high voltage test equipment, DC high voltage generator price.
Advantage
1.High accuracy and correct measuring. Voltage and current meter all have digital display, with voltage resolution 0.1kV, and current 0.1uA. Voltage value applied to load test object is displayed directly through voltmeter on control cabinet, which needn’t to be connected with voltage divider on the outside when using, and lead connection is easy
2.High stability in voltage regulation, smooth voltage regulation in full range. Voltage regulation of output adopts import single multi-rings potentiometer with rough adjustment and fine adjustment. Accuracy of voltage adjusting is better 0.1%, accuracy of voltage and current measuring is less than 1.0%, and ripple factor is better than 0.5%.
3.Negative polarity output, zero start, continuous adjustable, having the function of over voltage, over current, zero returning and ground protection. Operation is safe due to strong function of auto protecting circuit, technical index of all kinds surpassing industry standard and similar products.
Technical parameter
Specification
Technical Parameter
60/5
120/5
100/10
160/2
180/2
200/2
250/2
100/200 3/2
200/300 3/2
Others
Output voltage (kV)
60
120
100
160
180
200
250
100/200
200/300
600~800kV Produce according to the contract
Output current (mA)
5
5
10
2
2
2
2
3/2
3/2
Output power (W)
300
600
1000
320
360
400
500
400
600
Charging current (mA)
5.0
5.0
12.0
3.0
3.0
3.0
3.0
4.5/3.0
4.5/3.0
Case weight (kg)
4.5
7
5.3
4.3
4.3
4.4
4.5
4.5
8.1
Dimension of multivoltage tube (mm)
Φ80 ×500
Φ80 ×770
Φ80 ×770
Φ80 ×770
Φ110 ×770
Φ110 ×770
Φ110 ×820
Φ110 ×800
Φ110 ×1350
Height of multivoltage tube (kg)
7.3
9
7.5
7.2
7.2
7.2
7.6
7.5
12.6
HV polarity
Polarity of negative volt, zero voltage start, continuous adjustable
Work power
AC 220V±10%;50Hz
Voltage measuring accuracy
1.0%(full scale)±1character, max resolution 0.1%kV
Current measuring accuracy
1.0%(full scale)±1character, max resolution 0.1%uA
Over voltage rectify accuracy
≤1.0%
0.75 switch over accuracy
≤0.5%
Ripple factor
≤1.0%
Voltage stability
Random fluctuation, when voltage change of power supply±10% ≤0.5%
Work manner
Intermittent service; 30min of rated load;1.1 times of rated voltage use:10min
Temperature
-15℃~50℃
Relative humidity
When at 25℃,no more than 90%(no condensation)
Altitude
Below 2500m
More specifications can be customized .
Electric functional diagram
Several measurement methods
1.For general test, the test object connection wire must be suspended.Reading the corona and stray current I’ when rising to test voltage ,than connect test object and rise test voltage ,reading total current I1.
leakage current of test object:I0 = I1 –I’
2. When it is necessary to measure the leakage current of test object accurately, The GL type microammeter should be series connected at the high voltage side.
microammeter connect CX high voltage side of test object
The microammeter must equipped with metal shield and should be connected with the test object by a shielded wire.The shielding lead of the high voltage lead shall be closely connected with the shielding of the instrument end.
b wiring diagram for exclusion the effection from the test object Cχ surface
3. For zinc oxide and magnetic blow arrester(their grounding terminal can be separated), can adopt the test method of connecting in series of a current meter to the bottom of the test object.But shield lines must be used as the picture below.
4. After the test, return the voltage regulator to zero counterclockwise and turn off the power switch.
5.For small capacitance test object such as zinc oxide arrester, it can be discharged by measuring the voltage resistance inside the HV multivoltage tube.However, for large capacitance test object such as cables, the voltage of test products should be self-discharged to less than 20% of the test voltage.Discharge through the supporting discharge rod.After the test object is fully discharged and the ground wire is hung, the removal and replacement of the high-voltage lead are allowed
Turn off the power switch, the panel indicator light is not on.
Return the voltage regulator to zero.
After one minute,the standby low voltage capacitor will discharge fully,then it is allowed to turn on the power switch again. After the no-load test is carried out again and the situation is found out, the boost test can be carried out again. When the multivoltage tube is carried out without load, please tighten the crystal nut of multivoltage tube to prevent leakage.
Attentions
1. In order to ensure personal safety, users should pay attention to the good grounding of the control box and multivoltage tube as well as the discharge of test object and multivoltage tube after shutdown.
2. Prevent foreign matter from entering the control box. If there is a fan in the control box, check whether the fan operates normally.
3. When the multivoltage tube is dirty, please wipe with a dry cloth, not with alcohol, gasoline and other organic solvents scrub.Cleaning detergent can be used to clean the surface of multivoltage tube, and it can be used after air drying. Please put it into the box when it is transported or not used.
4. When replacing the fuse, please replace the fuse according to the measured amperage.
5.Without permission, do not disassemble the control box and multivoltage tube, or it will affect the product warranty, The factory shall not be responsible for self-demolition.
6. Rain erosion should be avoided when transporting the instrument, and collision and fall should be strictly prevented.
Package
Product description
1.99% of all delivered goods will be did factory test before shipping and guarantee that all our goods you get will be running well.
2.In case of missing /defective accessories,please notify us no later than 3 days after you receive the goods,then we will arrange re-shipment of the accessories.
3.Buyer has to us for the exchange notice before to returning goods,buyer will bear freight&handing fee.
4.We offer after-sell service within 1 year of purchase.we would bear the one way freight(from to you place).