Three Phase Power Analyzer for Transformer Testing

Model
Nature of the Manufacturer
Manufacturer
Product Category
Transformer Test Set
Place of Origin
City, Province
Overview
1.Waveform real-time display (4 channels voltage/4 channels current).2.True RMS values of voltages and currents.3.The DC components of voltages.4.Peak current and voltage values.5.Minimum and maximum half-cycle RMS current and voltage values.6.Pharos diagram display.7.Measurement of each harmonic up to order 50.8.Bar charts show harmonic ratios of current and voltage of each phase.9.Total harmonic distortion (THD).
Product Details
Brief introduction


This Three Phase Power Analyzer for Transformer Testing is mainly used for troubleshoot of complex power system more quickly and accurate, and monitoring and maintenance of power quality parameters more comprehensive and systemic.

It can simultaneously measure the 4-channel current (ABC three phase and neutral wire current), 4-channel voltage (ABC three-phase voltage and neutral line voltage to ground), the peak value of current voltage, maximum/minimum value over a period, three-phase imbalance factor, short-time voltage flicker, transformer K factor, active power, reactive power, apparent power, power factor and displacement power factor, active power, reactive power, apparent power, total harmonic distortion and harmonic, etc; Display real-time waveform, harmonic ratio bar charts of current voltage; Dynamically capture instantaneous change of voltage current, monitoring starting current, monitoring the power parameters and generate the alarm list, generate the trend chart for a long time record test data.

Three Phase Power Analyzer for Transformer Testing adopt DSP + ARM double processor architecture, DSP is use for data collection and the processing of algorithm, the ARM is use for the communication protocol and the man-machine interface processing;

Three Phase Power Analyzer for Transformer Testing apply to electricity industry, petrochemical, metallurgy, railway, mining enterprises, scientific research institution, metrological department. Especially suitable for comprehensive analysis and diagnosis on all the voltage, current, power, power, harmonic, phase electric parameters.


Functions


1.Waveform real-time display (4 channels voltage/4 channels current).

2.True RMS values of voltages and currents.

3.The DC components of voltages.

4.Peak current and voltage values.

5.Minimum and maximum half-cycle RMS current and voltage values.

6.Pharos diagram display.

7.Measurement of each harmonic up to order 50.

8.Bar charts show harmonic ratios of current and voltage of each phase.

9.Total harmonic distortion (THD).

10.Active, reactive, apparent power, by phase and cumulative.

11.Transformer K factor.

12.Power factors (PF) and displacement factors (DPF or COSΦ).

13.Short-term voltage flicker (PST).


Interface as below:

1(001)


Technical specification


Base condition and working condition

Influence factor

Test item

Base condition

Working condition

Environment temperature

All parameters

(23±2)°C

-10°C~ 40°C

Relative humidity

All parameters

40%~ 60%

<80%

Phase-to-neutral voltage

All parameters

(100±1%)V

1.0V~ 1000V

Phase-to-phase voltage

True RMS phase-to-phase voltage

(200±1%)V

1.0V~ 2000V

Current

True RMS current

(5±1%)A

10mA~ 1000A

Network frequency

All parameters

50Hz±0.1Hz

40Hz~ 70Hz


Phase shift

Active power and active energy

Cosφ=1

Cosφ: 0.2~ 1.0

Reactive power and reactive energy

Sinφ=1

Sinφ: 0.2~ 1.0

Harmonic

All parameters

<0.1%

0.0%~ 99%

Voltage unbalance

All parameters

<10%

0.0%~ 99%

Working voltage of device

All parameters

DC9.8V±0.1V

DC9.5V~ 10.5V

External electric field,
magnetic field

All parameters

Should be avoided


Test position

Measured related parameters of
current

Tested wire at the center of clamp.


General specification

Power supply

Rechargeable lithium-ion battery packs 9.6V, backup charger.


Battery indicator

Battery symbol shows dump energy. When the voltage is too low, automatic shutdown after the 1 minute.

Power consumption

Current consumption of normal test 490 mA, continuous working for 8 hours.

Display mode

LCD color screen, 640dots×480dots, 5.6 inches, display domain: 116mm×88mm.


Size of clamp

008B small sharp current clamp: 7.5mm×13mm; 040B circle current

clamp: 35mm×40mm;
068B circle current clamp: 68mm×68mm.
300F Flexible Coil Current Sensor (with Integrator) : Ф300mm

Instrument dimensions

L×W×H: 240mm×170mm×68 mm.

Number of channels

4U/4I.

Phase-to phase voltage

1.0V~2000V.

Phase-to-neutral voltage

1.0V~1000V.


Current

008B current clamp: 10mA~10.0A; 040B current clamp: 0.10A~100A;

068B current clamp: 1.0A~1000A;
300F Flexible Coil Current Sensor (with Integrator) : 10A ~ 3000A

Frequency

40Hz~70Hz.

Parameters of electricity

W, VA, Var, PF, DPF, cosφ, tanφ.

Energy parameters

Wh, Varh, Vah.

Harmonic

Order 0~50.

Total harmonic distortion

Order 0~50, each phase.

Expert mode

Yes.


Number of Transient
records

150 sets.

Voltage flicker

Yes.

Starting current mode

Yes, 100 seconds.

3 phases unbalance

Yes.


Record

300 days(simultaneous recording 20 parameters, record one point every 5 seconds).

Min/Max recorded value

Measurement of maximum and minimum values over a period of time.

Alarm

40 different types of parameter selections, 12,800 sets alarm logs.

Peak

Yes.

Phasor diagram display

Automatically.

Capacity of snapshots

60.

Menu language

English/Chinese.

Communication

USB.


Automatic switching off

When an alarm campaign is initiated or a search for transients, an inrush
current capture, or a trend recording is pending or in progress, the

device is not automatic switching off.

In other test mode, 15 minutes without keystrokes, automatic shutdown after prompt 1 minute.

Backlight function

Yes, suitable for use at night and dark place.



Weight

Host: 1.6kg (with battery).

008B small sharp current clamp: 170g×4;

040B circle current clamp: 190g×4;

068B circle current clamp: 510g×4;

300F Flexible Coil Current Sensor (with Integrator) : 330g×4;

Test wires and power adapter: 900g;

Total weight: about 9.2kg (with packaging).

Length of voltage test wire

3m.

Length of current sensor
wire

2m.

Working temperature and
humidity

-10°C~40°C; below 80%Rh.

Storage temperature and
humidity

-10°C~60°C; below 70%Rh.

Input impedance

Input impedance of test voltage: 1MΩ.


Withstand voltage

Withstand 3700V/50Hz sinusoidal AC voltage for 1 minute between

instrument wiring and shell.

Insulation

Between instrument wiring and shell ≥10MΩ.

Structure

Double insulation, with insulation vibration-proof sheath.


Safely rules

IEC 61010 1000V Cat III / 600V CAT IV, IEC61010-031, IEC61326,

Pollution degree: 2.


Service and Support


1.Strictly factory test for Three Phase Power Analyzer for Transformer Testing

All products will be assembled and test strictly according with our product process standard. All qualified products will be issued factory release reports and certificate labels.Defect products or non-qualified products won’t be allowed to make deliver.

2.Support technical guidance

We also provide the training for the operators. Complete training includes the skilled operations of our equipment, maintenance and troubleshooting . it also ranges the commissioning and test of our products at site!


Introduction


Wuhan Goldhome Electrical Equipment Co., Ltd .(abbreviated as Goldhome Hipot ) was established in 2008, formerly known as the third production enterprise of the national inspection unit, and then through the reform and recombination, we set up the high voltage testing equipment manufacturer.

Goldhome hipot adheres to the" integrity of management, quality-based" concept, dedicated to providing high-quality products and effciency & perfection after-sales service for our all customs,struggling for the global HV power doctor!

1

Similar Product Recommend