Welcome Customer !

Membership

Wuhan Goldhome Hipot Electrical Co., Ltd.
Free Member ·1YRS
WuHan,HuBei
Manufacturer

Main Products: High Voltage Tester|Automobile Exhaust Gas Analyzer

Xwboo>Products

CT PT Tester

Model
Nature of the Manufacturer
Manufacturer
Product Category
CT Analyser
Place of Origin
City, Province
Overview
Designed for automatic testing of protection and measurement CT/PT, suitable for laboratory and on-site testing. Support detection of CT and PT Meet the requirements of GB1207, GB1208 and other regulations. No need to connect other auxiliary equipment, a single machine can complete all test...
Product Details
I. Designed use


Designed for automatic testing of protection and measurement CT/PT, suitable for laboratory and on-site testing.


II. Main features


Support detection of CT and PT

Meet the requirements of GB1207, GB1208 and other regulations.

No need to connect other auxiliary equipment, a single machine can complete all test items.

Comes with a miniature fast printer, which can print test results directly on site.

Using intelligent controller, simple operation.

Large-screen LCD, graphical display interface.

The CT/PT (excitation) inflection point value is automatically given according to the regulations.

Automatically give 5% and 10% error curves.

3000 sets of test data can be saved, which will not be lost after power failure.

Support U disk transfer data, can be read through a standard PC, and generate WORD report.

Small and light weight ≤22Kg, very conducive to on-site testing.


III.Main test functions of the tester:


CT

PT

Volt-ampere characteristic (excitation characteristic) curve

Volt-ampere characteristic (excitation characteristic) curve

Automatically give the inflection point value

Automatically give the inflection point value

Automatically give 5% and 10% error curves

Ratio measurement

Ratio measurement

Polarity judgment

Polarity judgment

AC withstand voltage test

A flow test

Core demagnetization

AC withstand voltage test


Core demagnetization



IV. Main technical parameters of the tester:


project

Parameter

Power supply

AC220V±10% 、50Hz

Device output

0~1000V(20A Peak)

Note: 0~5A is the real value, more than 5A~20A is the calculated value

current output

0~600A

Excitation measurement accuracy

≤0.5%(0.2%*reading+0.3%*range)

CT

Ratio measurement

Scope

≤5000A/1A(25000A/5A)

Precision

≤0.5%

PT

Ratio measurement

Scope

≤500KV

Precision

≤0.5%

working environment

Temperature: -10℃ ~ 40℃, humidity: ≤90%, altitude: ≤1000m

size and weight

Size: 410mm × 260mm × 340mm, weight: ≤22Kg


V.Working condition requirements


1. Input voltage 220Vac±10%, rated frequency 50Hz;

2. The tester should be powered by a power outlet with a protective ground. If there is a problem with the connection of the protective ground, or the power supply does not have an isolated connection to the ground, the tester can still be used, but we do not guarantee safety;

3. The ambient temperature corresponding to the parameter is 23℃±5℃; the guaranteed value is valid within one year after factory calibration.、


VI.Operation mode and main interface


introductionHow to use the controller

The controller has three operating states: "Left Rotate", "Right Rotate", and "Press". These three operations using the controller can be conveniently used to move the cursor, enter data, and select items.

main menu

There are 7 options in the main menu: "Excitation", "Transformation Ratio Polarity", "AC Withstand Voltage", "One Pass Current", "Data Query", "Demagnetization", and "Return", which can be selected and set by the controller .

CT test

When performing current transformer excitation characteristics, transformation ratio, polarity, primary current, AC withstand voltage, and demagnetization tests, please move the cursor to "CT" and select the corresponding test options.


CT excitation (volt-ampere) characteristic test

After pressing the "Excitation" key, you will enter the test interface.


parameter settings:

Excitation current: The setting range (0-20A) is the highest setting current output by the instrument. If the current reaches the setting value in the experiment, the current will stop automatically to avoid damage to the equipment. Usually the current setting value is greater than or equal to 1A, and the inflection point value can be tested.

Excitation voltage: the setting range (0-1000V) is the highest setting voltage output by the instrument, usually the voltage setting value is slightly larger than the inflection point voltage, so that the ratio of the curve display can be more coordinated, the voltage setting is too high, the curve is close to the Y axis, and the voltage setting is too high Low, the curve is close to the X axis. If the voltage reaches the set value during the experiment, the boost will be automatically stopped to avoid damage to the equipment.


Similar Product Recommend