Welcome Customer !

Membership

Wuhan Goldhome Hipot Electrical Co., Ltd.
Free Member ·1YRS
WuHan,HuBei
Manufacturer

Main Products: High Voltage Tester|Automobile Exhaust Gas Analyzer

Xwboo>Products

Gas Leak Detection Device

Model
Nature of the Manufacturer
Manufacturer
Product Category
Sf6 Analyzer
Place of Origin
City, Province
Overview
Measuring range (SF6): 0.01ppm~500ppm (volume ratio)Response time: no more than 3 secondsIndication mode: LCD digital display and sound and light signal alarmAlarm setting range: 0.01ppm~500ppm (volume ratio)Pumping speed of vacuum pump: 0.5L/secVacuum pipe length: 4 metersContinuous working time: no more than 4 hoursWorking conditions: AC power supply 220V 50Hz
Product Details
Product profile


The principle of the SF6 gas leak detection device is: when the concentration of sulfur hexafluoride gas contained in the air changes, the degree of ionization of the mixed gas under the action of high-frequency electromagnetic field will also be different, and the degree of ionization can be reflected by detecting the degree of ionization. Sulfur concentration.

The Gas Leak Detection Device uses a small vacuum pump, and the probe and the host are separated. It has the characteristics of small size, light weight, convenient carrying, high sensitivity, good stability, fast response speed, the probe will not be poisoned, and no toxic gas will be produced. And there is a liquid crystal display gas concentration, making the instrument reading more convenient and accurate.

The Gas Leak Detection Device has a new alarm setting function, when the measured gas concentration is greater than or equal to the set value, it will automatically sound an alarm.

This Gas Leak Detection Device is specially used in electric power, railway, electrical appliance manufacturing, chemical industry, fire-fighting equipment, and atomic physics scientific research departments for leak detection of equipment and containers filled with sulfur hexafluoride. It can quickly and accurately detect qualitatively and quantitatively.


ITechnical parameter


Measuring range (SF6): 0.01ppm~500ppm (volume ratio)

Response time: no more than 3 seconds

Indication mode: LCD digital display and sound and light signal alarm

Alarm setting range: 0.01ppm~500ppm (volume ratio)

Pumping speed of vacuum pump: 0.5L/sec

Vacuum pipe length: 4 meters

Continuous working time: no more than 4 hours

Working conditions: AC power supply 220V 50Hz

Environment temperature 7℃-40℃

Relative humidity is not more than 85%

Power: about 180W

Whole machine weight: about 15Kg


Product structure

1

1 Detection switch

2 Power switch

3 power socket

4 AC fuse (0.5A)

5 DC fuse (5A)

6 Host

7 Needle valve

8 Handheld probe

9 LCD display

10 Nuttons

11 Ionization chamber observation window

12 Gas and electricity pipeline


Attention


1. Keep the entire Gas Leak Detection Device clean and tidy to prevent debris from entering the probe and vacuum pump. The entire instrument should be placed in a ventilated and dry place to avoid moisture.

2. The probe needle valve of the instrument has been adjusted before leaving the factory, generally do not adjust. Due to improper use or some reasons, the needle valve position changes, the needle valve should be re-adjusted until the amount of air intake is appropriate. The output voltage and signal output value of the three adjustable potentiometers inside the probe have been adjusted before leaving the factory. Generally, no adjustment is required. If adjustment is required, please refer to the technical parameters of the instrument for adjustment, otherwise the internal components of the instrument will be burned out. Device. Every time the instrument adjusts the internal potentiometer, the instrument must be re-calibrated, otherwise the measurement data will be inaccurate.

3. Due to long-term use, the aging of the "O"-shaped rubber gasket at the needle valve connection port will cause air leakage at the connection to affect the vacuum degree, and it should be replaced immediately.

4.The instrument must not be turned upside down or vibrated violently to prevent the probe and the adjustable components in the machine from leaving the position and affecting the performance of the instrument.

5.If the instrument is turned on, if there is a screen or no display, press the key and then the exit key to refresh.

2


After-sale service


1.First-use responsibility system

After the product is delivered, the technician can guide the operation at site if the client requires, and be responsible for the first use of each part

2.One year warranty

All products warranty is 1year, life-time maintenance .

During the warranty period, if any defects or damaged because of product’s quality, maintenance or replacement can be provided with free charge in order to let our client’s satisfied !

3.Trouble-shooting

fault that users can solve by themselves, we guarantee to give timely telephone guidance and bear the necessary cost .

If meet any fault not impossible to be solved by end-user, we will afford the best solution within 24 hours . Produce will be repaired within 10 days and delivery back to customer.


After-sales Service Commitment


1.We guarantee that professional engineers and technicians will answer qustions by telephone, or other channel within 1 hour, deal with equipment failure in time within 24 hours.

2.Upon receipt of the client's request for after-sales service,we promises to provide solutions within 48 hours.

3.We will provide relevant technical training and technical information according to client's requirements.

4.The product can be repaired free of charge for one year and maintained for life.

Similar Product Recommend