Phase :single phaseFrequency:50HzRated capacity:150kVAInput voltage:0.4kVInput current:375A Output voltage:0~280kVOutput current: 0.53AWaveform deviation factor:≤3%Measurement winding voltage ratio:1000:1Insulation level: low voltage input terminal to ground power frequency voltage withstand level 5kV/1minDielectric loss: <0.3%Noise:≤60dB
Product Details
Introduction
Power frequency Partial Discharge Equipment is used for checking the insulation level of all kinds of insulation materials ,insulation structure and electric products. Partial Discharge Equipment is also can be regarded as the partial discharge power source for the power transformers, capacitors, HV vacuum tubes ,CT PT, arrestors and other tested objects. Partial Discharge Equipment is widely adopted by electric manufacturers,electric running departments. Research unities and universities.
Partial discharge hipot tester features
1.This Partial Discharge Equipment specification is complete(from 10kVA/50kVto 1000kvA/1000kV ), even higher. All capacity and voltage levels we can customized, functions are improved.
2.The oil-filled testing transformer adopts the partial discharge epoxy insulated cylinder, it will make sure the minimum partial discharge amount. This craft is obvious advantage of field companies.
3.We adopts the high quality silicon steel sheet: DQ130-30 with grain oriented,45 ° inclined seams laminated,the waveform distortion and no-load current is the minimum in the domestic market.
4.Impedance voltage is very low, it is higher than the IEC standard.
5.The console adopts automatic industrial PLC system with computer photo-electricity skill.it has strong anti-interference and higher-automatic features.
6.It has quick-reflection electric protection system,very stable and shorten the harmless to devices.
PD hipot tester main parameters for 150kvA/280kV
1.Technical Parameter for Test Transformer
Phase :single phase
Frequency:50Hz
Rated capacity:150kVA
Input voltage:0.4kV
Input current:375A
Output voltage:0~280kV
Output current: 0.53A
Waveform deviation factor:≤3%
Measurement winding voltage ratio:1000:1
Insulation level: low voltage input terminal to ground power frequency voltage withstand level 5kV/1min
Dielectric loss: <0.3%
Noise:≤60dB
Partial discharge: 0-250kV ,the partial discharge is ≤1-3PC; 0-280kV, the partial discharge is ≤3-5pc
Running time: under rated voltage and current,start form environment temperature,can run 30min.
under 2/3 rated voltage and current, continuous running.
Single test transformer impedance : 3%-12%
Waveform deviation factor: <3%
2.Technical Parameter for Automatic console
Phase:single phase
Frequency:50Hz
Rated capacity:150kVA
Input voltage:0.4kV
Input current:375A
Output voltage:0~400V
Output current:0.53A
Waveform deviation factor:≤3%
Insulation level: low voltage input terminal to ground power frequency voltage withstand level 5kV/1min
Insulation level:<0.3%
Noise: ≤60dB
Partial discharge: 0-400V , the partial discharge ≤1-3PC
Running time: under rated voltage and current,start form environment temperature,can run 30min. under 2/3 rated voltage and current, continous running.
3.Technical Parameter for for coupling voltage divider
Mode: HM-TRF-280
Rated frequency: 50Hz
Capacity: 500PF10%
Rated voltage : 280kV
Divider ratio: 1000:1
Dielectric loss:<0.5%
Precision: 1.5
Partial discharge: under 280kV , ≤3~5PC; under 250kV, ≤1~3PC
Error rang of capacity and divider ratio: ±1.5%
Loss Angle tangent of capacitor dielectric: Pure capacitor voltage divider, under 20℃, 0.4-0.5UN, tgδ≤0.0025.
4.Technical parameter for power isolating transformer
Mode: HM-GLB-150/0.4
Rated capacity:150kVA
Rated voltage ratio:0.4/04kV
Rated current ratio :375/375A
Rated frequency: 50~60Hz
Number of line:2 line
Quality factor of filter reactor:>70
Partial discharge background level : under 280kV, ≤3~5PC; under 250kV, ≤1~3PC
For the first time use, technical staff will guide customer how to make testing at site.
Three-years Warranty
The warranty period of all equipment is three years, lifetime maintenance.
During warranty period, free maintenance or replacement are provided timely for any quality problem . Finally we will afford customer a satisfactory solution, whether repair, replace or return it back.
Trouble-shooting
fault that users can solve by themselves, we guarantee to give timely telephone guidance and bear the necessary cost .
If meet any fault not impossible to be solved by end-user, we will afford the best solution within 24 hours . Produce will be repaired within 10 days and delivery back to customer.