Welcome Customer !

Membership

Ivy Metering Co., Ltd.
Free Member ·1YRS
ShangHai,ShangHai
Manufacturer

Main Products: Circuit Breakers

Xwboo>Products

MD0630T01A Compact PCB Mount RCD Residual Current CT AC DC Leakage Current Sensor for Level 2 Cha...

Model
Nature of the Manufacturer
Manufacturer
Product Category
American Market
Place of Origin
City, Province
Overview
MD0630T01A Compact PCB Mount RCD Residual Current CT AC DC Leakage Current Sensor for Level 2 Charger
Product Details

Product Introduction

IVY offers MD0630T01A for monitoring and/or providing shock protection and fault protection on AC and DC installations and for EV charging applications. MD0630T01A is a RCD sensor specifically developed for EV-charging providing all-current sensitivity. The sensor can issues an alarm signal in case of hazardous electrical faults (DC and AC). It has the characteristics of accurate measurement, small size and integration. The RCD sensor can be set separately for AC and DC leakage and has a digital output function. MD0630T01A is an automotive grade leakage current sensor from IVY also called residual current monitoring (RCM), residual current detection (RCD), differential current sensor, leakage current detector and fault current sensor. Type A, B and B+, dedicated to detect to DC, AC and DC+AC leakage current measurement. The MD0630T01A can monitor DC (6mA) and AC (30mA) residual currents, it is connected in series with the AC supply to an EV and will provide a signal output if a DC current ≥ 6mA DC flows in the circuit. In addition, our delivery time is also guaranteed.


Product Description

This product is fully compliant with TUV/CE-EMC 
The MD0630T01A is a residual current monitor intended for the detection of DC and AC residual currents in 50Hz/60Hz AC installations.
The MD0630T01A is primarily intended for use in Mode 2 Electric Vehicle In-Cable Control and Protection Devices (IC-CPDs) and Mode 3 Wallbox Charger, to disconnect the supply to the Electric Vehicle under an AC or DC residual current fault condition.
The MD0630T01A may also be used to detect DC or AC residual currents in DC, single phase or multiphase installations.
The MD0630T01A is a compact solution designed to be mounted directly onto a PCB.


MD0630T01A 6mA DC Leakage Protection RCD Sensor Residual Current Monitor for 3phase 32A AC Charger


Product Features

1. Complies with the DC and AC protection requirements of IEC62752 or IEC62955

2. Small Size; Integration Design; Vertical(Pin, Pin&Cable Type)/Horizontal(Cable Type) Mounting Optional

3. Integrated self-monitoring and test functions; 3000A surge withstand capability

4. AC DC Leakage Data Readable; Alarm Value Programmable; 3 Way Alarm Outputs; Digital Output

5. URAT Comm, with Modbus Protocol; Standard: EN 61000-6-3:2007+A1, EN IEC 61000-6-1:2019

6. Certification: TUV(IEC62955/IEC62752/IEC61851-1/IEC62196); UL2231-1/UL2231-2; IS17017; CE-EMC 

7. Type B RCD/RCM for EV Charger Protection; Electrical Safety at Low Cost (Compared to Type B RCCB)

8. Robust Mechanical and Electrical Design for Harsh Environmental Conditions


Pin Definition

image.png

Pin

Definition

Description

1

Vcc

12V±20% input voltage

2

GND

Input terminal grounded

3

RX

UART receive(UART output voltage 5V)(Modbus Protocol)

4

TX

UART transmit(UART output voltage 5V)(Modbus Protocol)

5

AD

AC、DC leakage alarming output( output voltage 5V)(Digital Signal)

6

AO

AC leakage alarming output( output voltage 5V)(Digital Signal)

7

DO

DC leakage alarming output(output voltage 5V)(Digital Signal)


Product Parameters

  • Wide voltage input: 12V±20%

  • Measuring current range: DC current 2-15mA; AC current 3-100mA (default threshold: DC 6mA, AC 30mA)

  • Accuracy : at 25℃, DC±0,2mA, AC±0.3mA

  • Can read current value and set alarm current value

  • Three outputs: DC alarm, AC alarm, AC/DC alarm

  • Working environment temperature: -25℃~+80℃

  • Plastic case, small SIP package


Why a DC 6mA or a Type A/B RCD been required in IC-CPD and AC Charger/Wall-Box application?

The existing type A RCD can only in the detection of pulsating dc leakage from 6 mA dc current interference, and can’t detect dc leakage and disconnect protection, when DC leakage is more than 6 mA, due to the DC residual current will cause core magnetization in advance, make tripping value deviation, lead to type A RCD can’t normal movement. Therefore, type B RCD or A+6mA protection must be used!

MD0630T01A Mode 3 AC DC Protection Leakage Sensor RCD Modules for 3phase 22KW Wallbox Charger


Typical Application

As the residual current protective devices (RCD) is widely used in low-voltage distribution system to prevent electric shock accidents, leakage damage of electrical equipment and fire caused by electrical leakage. MD0630T01A residual current monitoring module monitors and immediately stops electrical risks that can occur during below Applications. 

  • Ground fault current detection

  • Solar inverter residual current 

  • Converter leakage current detection 

  • UPS and other power ground fault detection

  • Electric vehicle charging station

  • Single or 3 Phases differential current detection