MD0630T41A TUV/CE Differential Current Monitoring 6mA DC Leakage Current Sensor for Mode 3 EV Charging
Product Details
Charging of electric vehicles at a standard wall socket or a wall box requires protection devices against DC fault currents to avoid electric shock. Installed type A residual current circuit-breakers (RCCBs) are unable to identify and deactivate DC fault currents. IVY differential current sensors offer the opportunity to save the cost and space for a costly type B RCD in IC-CPD or wall boxes.
MD0630T41A is a leakage current sensor(RCD/RCM) for Electric Vehicle Charging Station. It has the characteristics of high sensitivity, correct measurement, small size and compact/integration design. The leakage current detector can be set separately for AC and DC leakage. When the set current is reached, an alarm signal is generated, and the switch control signal is output at the same time. The RCD sensor is connected in series with the AC supply to an EV and will provide a signal output if a DC current ≥ 6mA DC flows in the circuit. It will protect against DC (6mA) and AC (30mA) residual currents, and will signal to the Smart EVSE if a fault occurs.
MD0630T41A residual current monitor is a differential current (DI) sensor specifically developed for EV-charging, providing all-current sensitivity. Type B RCD/Type A + 6ma dc residual current module combination for EV charger pile protection, all-in-one highly integrated digital output. MD series residual current monitor is an ideal protection device, for the detection of different leakage currents/residual currents/fault currents in applications of DC screen, Fire distribution cabinet, PV inverters, medical equipment, UPS devices, EV charging facilities etc.

Product Features
1. Fixed 6mA DC and 30mA AC trip levels; 3000A surge withstand capability; "Fault" output – Open collector
2. Small Size, Integration Design, Vertical(Pin, Pin&Cable Type)/Horizontal(Cable Type) Mounting Optional
3. Integrated self-monitoring and test functions, Digital Output, Residual Fault Leakage Current Protection
4. AC DC Leakage Data Readable; Alarm Value Programmable; 3 Way Alarm Outputs
5. URAT Comm, with Modbus Protocol; Standard: EN 61000-6-3:2007+A1 ,EN IEC 61000-6-1:2019
6. Professional Certification: TUV(IEC 62955/IEC 62752/IEC 61851-1); UL 2231-1/UL 2231-2; CE-EMC
7. Used in EV Charger Project (Load current up to 80 Arms (1-phase) or 3 x 32 Arms (3-phase))
Product Parameters
Wide voltage input: 12V±20%
Measuring current range: DC current 2-15mA; AC current 3-100mA (default threshold: DC 6mA, AC 30mA)
Accuracy class: at 25℃, DC±0,2mA, AC±0.3mA
Working environment temperature: -25℃~+80℃
Installation: Pin&Cable Type
Plastic casing: SIP encapsulation
Typical Application
Charging mode 2
IC-CPD in charging cables for electric vehicles (EV) and plug-in hybrid electric vehicles (PHEV)
Charging mode 3
Wallboxes for charging EV and PHEV
Charging piles for charging EV and PHEV