MD0630T01A Type B RCD 6mA DC 30mA AC Zero Phase Leakage Current Sensor for E-mobility Project
Product Overview
MD0630T01A is a high sensititivity Type B (Type A + 6ma dc detection) leakage current sensor for electric vehice charging station, which can also be called residual current sensor, residual current monitor (RCM), residual current device(RCD), differential current sensor, zero phase current sensor, fault current sensor etc. MD0630T01A RCD is intended to detect dangerous residual currents and thereby mitigate the risk of electric shock or fire. In the case of EV charging, there is a risk of AC and DC residual currents, and it is vitally important that the RCD can be used to detect AC and DC residual currents. It is suitable for integration into a charging unit (IC-CPD, wall box) according to IEC 61851-1, IEC 62752 and UL 2231-1. It can monitor DC (6mA) and AC (30mA) residual currents, and will signal to the Smart EVSE, if a fault occurs.
When a current exceeding 30mA passes through the human body the individual will be at serious risk of a fatal electric shock if the current is not interrupted in a timely manner. Type A/ Type B zero phase residual current sensor made by IVY is widely used in GFCI, residual current device and other electrical safety protection device like EV Charging. These devices will issue an alarm signal when it detects that current is flowing along an unintended path, such as through water or a person. It is used to reduce the risk of electric shock, which can cause the heart to stop or cause burns. They can also prevent some fires, like when a live wire touches a metal conduit. In addition, our delivery time is also guaranteed.

Product Features
1. Complies with the DC and AC protection requirements of IEC62752 or IEC62955
2. Small Size, Integration Design, Vertical(Pin, Pin&Cable Type)/Horizontal(Cable Type) Mounting Optional
3. Integrated self-monitoring and test functions; 3000A surge withstand capability
4. AC DC Leakage Data Readable; Alarm Value Programmable; 3 Way Alarm Outputs; Digital Output
5. URAT Comm, with Modbus Protocol; Standard: EN 61000-6-3:2007+A1 ,EN IEC 61000-6-1:2019
6. Professional Certification: TUV(IEC62955/IEC62752/IEC61851-1/IEC62196); UL 2231-1/UL 2231-2; IS17017; CE-EMC
7. Type B RCD/RCM for EV Charger Protection; Electrical Safety at Low Cost (Compared to Type B RCCB)
8. Robust Mechanical and Electrical Design for Harsh Environmental Conditions

Product Parameters
Wide voltage input: 12V±20%
Measuring current range: DC current 2-15mA; AC current 3-100mA (default threshold: DC 6mA, AC 30mA)
Accuracy : at 25℃, DC±0,2mA, AC±0.3mA
Can read current value and set alarm current value
Three outputs: DC alarm, AC alarm, AC/DC alarm
Working environment temperature: -25℃~+80℃
Plastic case, small SIP package
Typical Application
Appliance ground fault detection
Solar inverter residual current
Converter leakage current detection
UPS and other power ground fault detection
Electric vehicle charging station
Single or 3 Phases differential current detection