MD0630T01A EV Residual Current Monitoring Unit Leakage Sensor GFCI Transformer for Type 2 Charging Cable
Product Overview
MD0630T01A is a high sensititivity AC DC leakage current sensor which has the characteristics of accurate measurement, small size and integration. The leakage sensor can be set separately for AC and DC leakage. An alarm signal is generated when the set current is reached. The leakage sensor has a digital output function, which can directly read the current value of DC and AC. Which can also be called residual current sensor, residual current monitor (RCM), residual current device (RCD), differential current sensor, leakage current detector and fault current sensor etc. The residual current detection sensor is used as RCD Type A, B and B+, sensor dedicated to DC, AC or pulsed leakage current measurement in automotive on-board chargers. IVY sensor family give you the choice of having single or three-phase versions as well as safety version in the same housing and provide fast digital tripping output when leakage current is detected.
A “ground fault" is a conducting connection between any electric conductor and any conducting material that is grounded or that may become grounded. Electricity always wants to find a path to the ground. In a ground fault, electricity has found a path to ground, but it is a path the electricity was never intended to be on, such as through a person’s body.Because of this potential for shock, GFCI/RCD protection is used to protect human life. This residual current monitor is intended for the detection of DC and AC Residual currents in EV Charging Stations where such currents may flow under a fault condition. The RCD/RCM device may be used to detect 6mA DC or 30mA AC Residual Currents in DC, single phase or 3 phase installations, it is ideally suited for use with Electric Vehicle charging cables (Mode 2 Protection) and EV charging stations (Mode 3 Protection). When a Residual Fault Current that exceeds the rated AC or DC level is detected, It will signal to the Smart EVSE.

Product Features
1. Complies with the DC and AC protection requirements of IEC62752 or IEC62955
2. Small Size, Integration Design, Vertical(Pin, Pin&Cable Type)/Horizontal(Cable Type) Mounting Optional
3. Integrated self-monitoring and test functions; 3000A surge withstand capability
4. AC DC Leakage Data Readable; Alarm Value Programmable; 3 Way Alarm Outputs; Digital Output
5. URAT Comm, with Modbus Protocol; Standard: EN 61000-6-3:2007+A1 ,EN IEC 61000-6-1:2019
6. Professional Certification: TUV(IEC 62955/IEC 62752/IEC 61851-1); UL 2231-1/UL 2231-2; IS17017; CE-EMC
7. Type B RCMU for EV Charger Protection; Electrical Safety at Low Cost (Compared to Type B RCCB)
8. Robust Mechanical and Electrical Design for Harsh Environmental Conditions
Product Parameters
Wide voltage input: 12V±20%
Measuring current range: DC current 2-15mA; AC current 3-100mA (default threshold: DC 6mA, AC 30mA)
Accuracy : at 25℃, DC±0,2mA, AC±0.3mA
Can read current value and set alarm current value
Three outputs: DC alarm, AC alarm, AC/DC alarm
Working environment temperature: -25℃~+80℃
Plastic case, small SIP package
EV Charging Application:
MD series residual current sensor (RCD/RCM) is an ideal protection device, for the detection and protection of different leakage currents/residual currents/fault currents. The RCD could quickly output alarm signal when people get an electric shock or leakage current exceeds stipulated value, protecting personal and electrical equipment safety. MD series leakage current detector have numerous applications and are suitable for many industries including electric vehicle charging, photovoltaic systems, industrial device, medical device, new energy, DC screen, fire distribution cabinet, IOT field and any installation where there is a risk of DC current flowing. It is the technology that brings us closest to total protection for all known residual fault currents.