TRSS-DB Serial Port Signal Surge Arrester Protector
Production introduction:
TRSS-DB9 and TRS-DB25 surge protector are designed to protect sensitive equipment linked to datalines equipped with D-sub connectors, as RS232, RS422 and RS485lines. They are equipped with D-sub connectors for fast and easy maintenance. In order to comply with the line configuration, all the wires are transmitted and protected.
Product Feactures:
1. D-Sub surge protector
2. For RS422 communication lines
3. 9-pin connector
4. Fast and easy installation
5. Secondary protection
Electrical Characteristics |
Type | TRSS-DB9 | TRSS-DB25 |
Nominal working voltage (DC)UN | 12 V | 12 V |
Maximum continuous working voltage(DC)Uc | 18 V | 18 V |
Rated current at 45℃ IL | 100 mA | 100 mA |
Nominal discharge current per line(C2, 8/20μs) In | 0.1 kA | 0.1 kA |
Line-line voltage protection level(C2, 8/20 μs) Up | 60 V | 60 V |
Line-PE voltage protection level(C2, 8/20 μs) Up | 600 V | 600 V |
Line-line voltage protection level(C3, 1kV/μs) Up | 60 V | 60 V |
Line-PE voltage protection level(C3, 1kV/μs) Up | 600 V | 600 V |
Line-line voltage protection level(B2, 1kV@10/700μs) Up | 60 V | 60 V |
Line-PE voltage protection level(B2, 1kV@10/700μs) Up | 600 V | 600 V |
Line-line response timetA | 1 ns | 1 ns |
Line-PE response timetA | 100 ns | 100 ns |
Series resistance R | 0 ohm | 0 ohm |
Enclosure rating | IP20 |
Grounding method | Lead wire |
Shell material | ABS |
Body color | Beige/black |
Circuit Diagram:
Dimension: