| Diameter | DN350-1400 mm |
| Capacity | 900-12500 m3/h |
| Head | up to 20m |
| Liquid Temperature | up to 50 ºC |
Installation of Suction and Discharge Pipes
1.Suction Pipe: according to the outline drawing in the booklet. The smallest depth of the pump under the water should be bigger than the datum in the drawing.
2.Discharge:flap valve and other methods.
3.Installation: MVS series are suitable for elbow cantilever installation, well cantilever installation and concrete well cantilever installation.
Motor
Submersible Motor(MVS series) Power class: electric performance meets GB755
Protection class:IP68
Cooling system:ICWO8A41
Basic installation type: IM3013
Voltage: up to 355kw, 380V 600V 355KW, 380V 600V ,6kv, 10kv
Insulation class: F
Rated power: 50Hz
Length of cable: 10m
Shaft Seal
This type has two or three mechanical seals. The first seal, which contacts water, is usually made of carbon silicon and carbon silicon. The second and third are usually made of graphite and carbon silicon.
Leakage Protection
MVS AVS series has leakage protection sensor. When the oil house of motor or the wire-box is leaking, sensor will give out warning or stop working and maintain the signal.
Overheat Protector
The winding of MVS series submersible motor has overheat protector. When it is overheated, warning will be given out or the motor will stop working.
Rotating Direction
Looking from upper side, the impeller is rotating clockwise.
Series Definition