3RWGM30/50/75 & 3RWM50K60-900K (Modular UPS)

Model
Nature of the Manufacturer
Manufacturer
Product Category
Online Transformerless UPS
Place of Origin
City, Province
Overview
3RWGM30/50/75 & 3RWM50K60-900K (Modular UPS)
Product Details
Product parameters

3RW30/50/75 & 3RWM50K60-900K (Modular UPS)


3RW Series Modular UPS

1. Modular Design

3RW Series is the rack modular design, Seamlessly integrated with the latest data center designs, It is a true modular system, consists of dedicated redundant modules -- power supply, smart module, battery, and bypass.

image.png

2. High efficiency

3RW modular UPS is high efficiency, when at AC mode full loads, it is ≥94%. And the output power factor is up to 1.0.

3. Hot Swap for power modular and battery

The number of battery cells can be configured flexibly, so the original batteries can be used when modifying the legacy system; moreover, Power modular can be replaced in time when it fails without interrupting the normal operation of UPS.

4. N+1 or N+X parallel redundancy for power guarantee

Scalable architecture allows you to optimize cost expense to meet power demands by vertically expanding in a single rack enclosure from 60KVA to 900KVA and achieve N+1 or N+X redundancy in the same rack.

5. LCD Display

The intuitive design of 7 inches LCD touchable display enhances the readability of identified and advanced configuration.

显示屏.jpg

6. Adjustable Charging Current and battery voltage

3RW modular UPS provide maximum 5A charging current per modular and battery voltage can be set from 32pcs to 44pcs per string. They are user-adjustable based on requirement.

7. Communication ports

UPS supports RS485, RS232 communication and network port (LAN) communication, simple network monitoring (SNMP) protocol communication, Mod-bus protocol communication, YD/T 1363.3-2005 protocol communication and dry contact communication.

8. Friendly-environment

Input power factor ≥0.99, input current harmonic <5%, improve power utilization, effectively avoid additional energy loss, eliminate pollution to the grid, reduce energy consumption costs.

9. Input &output phase

3RW series modular UPS can be configured to 3/3, 3/1,1/1


3RW Power Modular Technical Specification

Module Model

GM30

Module Capacity

30KVA

Input/Output Way

Three phase in three phase out

Module Dimension(W*D*H)mm

440*590*130

Weight(kg)

32 kg

Input PF

≥0.99

Input Total Harmonic Distortion THDI(%)

≤3%



3RW System Technical Specification

Model

3RWG90KM30

3RWG150KM30

3RWG180KM30

3RWG240KM30

3RWG270KM30

Capacity

90KVA

150KVA

180KVA

240KVA

270KVA

Type of power module

GM30

Input mode

3 Phase 4 Wires+ Ground

Input voltage(Vac)

380V/220V±20%、400V/230V±20%、415V/240V±20%

Input Frequency(HZ)

50Hz±10%、60Hz±10%

Input PF

≥0.99

Battery voltage(Vdc)

±240

Charge Time

10hs (2hs backup battery capacity)

Battery quantity(Pcs)

32-44 can be adjusted

UPS Power Factor

1.0

Output Voltage(Vac)

380/220V、400/230V、415/240V

Output Frequency(HZ)

50Hz±4%;Mains overrun or battery mode output is 50Hz±0.2%

60Hz±4%;Mains overrun or battery mode output is 60Hz±0.2%

Output voltage Stability

±1%(Static);±2%(Load change from 0 ~ 99% )

Efficiency (AC mode @ full loads)

≥94%

Output voltage recovery time

<20ms(Load change from 0 - 99% )

Overload

Rated load 125% ,runs 10mins

Communication function

RS232/RS485/422/ dry contact/TCP/IP Expansion cards

SMMP(optional)

Can be network monitored by SNMP adapter

Parallel function

Yes(for optional)

Alarm

Battery low-voltage, mains abnormal, overload, UPS fault, over temperature protection

Working Environment Temperature

-5℃~40℃

IP Class

IP31

Cooling

Speed controlled air cooling

Noise(dB)

≤55dB(Within 1 meter)

Structure

19 inches Standard

Monitor Management System

UP Supervisor

Display

Touchable screen LCD/LED

Dimension(W*D*H)

600×800×1200

600×800×1600

600×800×1600

600×800×2000

600×800×2000

Weight (Kg)

120KG

140KG

160KG

200KG

250KG


3RW Power Modular Technical Specification

Module Model

M50

M75

Module Capacity

50KVA

75KVA

Input/Output Way

Three phase in three phase out、three phase in single phase out、single phase in three phase out、single phase in single phase out

Input PF

≥0.99

Input Total Harmonic Distortion THDI(%)

≤3%

Module Dimension(W*D*H)mm

482*700*176

682*700*176

Weight(kg)

40 kg

50 kg


3RW System Technical Specification

Model

3RW200KM50

3RW300KM50

3RW400KM50

3RW500KM50

3RW600K

M50

3RW450KM75

3RW600KM75

3RW900KM75

3RW1200KM75

Capacity

200KVA

300KVA

400KVA

500KVA

600KVA

450KVA

600KVA

900KVA

1200

Type of power module

M50

M75

Input mode

3Ph+N+PE

Input voltage(Vac)

380V/220V±20%、400V/230V±20%、415V/240V±20%

Input Frequency(HZ)

50Hz±10%、60Hz±10%

Input PF

≥0.99

Battery voltage(Vdc)

±240

Charge Time

10hs (2hs backup battery capacity)

Battery quantity(Pcs)

32-44 can be adjusted

UPS Power Factor

1.0

Output Voltage(Vac)

380/220V、400/230V、415/240V

Output Frequency(HZ)

50Hz±4%;Mains overrun or battery mode output is 50Hz±0.2%

60Hz±4%;Mains overrun or battery mode output is 60Hz±0.2%

Output voltage Stability

±1%(Static);±2%(Load change from 0 ~ 99% )

Efficiency (AC mode @ full loads)

≥94%

Output voltage recovery time

<20ms(Load change from 0 - 99% )

Overload

Rated Load 125% ,runs 10mins

Communication function

RS232/RS485/422/ dry contact/TCP/IP Expansion cards

SMMP(optional)

Can be network monitored by SNMP adapter

Parallel function

Yes(for optional)

Alarm

Battery low-voltage, mains abnormal, overload, UPS fault, over temperature protection

Working Environment Temperature

-5℃~40℃

IP Class

IP31

Cooling

Speed controlled air cooling

Noise(dB)

≤55dB(Within 1 meter)

Structure

19 inches Standard

Monitor Management System

UP Supervisor

Display

Touchable screen LCD/LED

Dimension(W*D*H)

600×1000×2000

800×850×2000/ 900×1000×2000

900×1000×2000

1400×850×2000/ 1200×1000×2200

1200×1000×2000

900×1000×2000

1200×1000×2000

1800×1000×2000

2000×1000×2200

Weight (Kg)

200

250

320

400

500

400

540

600

700


Note:1, Because the products are continuously improved, please contact the company or dealer to inquiry the latest specification.

3RWGM30/50/75

3RWGM30/50/75

3RWGM30/50/75

3RWGM30/50/75

3RWGM30/50/75

3RWGM30/50/75