Welcome Customer !

Membership

Jiangsu Imposol New Energy Co., Ltd.
Free Member ·1YRS
ChangZhou,JiangSu
Manufacturer

Main Products: Solar Water Heater|Water Tank Storage Equipment

Xwboo>Products

SR658(SR618C6) Solar Hot Water Controller

Model
SR658
Nature of the Manufacturer
Manufacturer
Product Category
Split Pressure Series Controller
Place of Origin
City, Province
Overview
SR658(SR618C6) Solar Hot Water Controller
Product Details

INTRODUCE

SR658 Controller Is The Updated Version Of The SR618C6 Controller .

  1. 19 systems can be programmer

  2. Support firmware update by SD card


For below solar hot water system  :

  1. Split type high pressure system 

  2. Split type Low / Non pressure system + Assistant tank with float ball


APPLICATIONS CAPACITY

  1. Max.number of collectors:2

  2. Max.number of storage tanks:2

  3. Max.number of relays:6

  4. Max.number of sensors:8

  5. Max.number of visualization application system:19

  6. Signal port for HE pump:PWM1,PWM2,PWM3

  7. FRT:1*Digital flowmeter sensor

  8. VFS:1*Grundfos flowmeter sensor



TECHNICAL DATA

  1. Size of Controller: 208mm x158mm x43mm

  2. Power supply: AC100-240V,50-60Hz. .  

  3. Power consumption: < 2.5W

  4. Rated impulse voltage: 2.5KV

  5. Data interface: TF(micro SD)

  6. Housing: Plastic ABS

  7. Protection type: IP41

  8. Protection class: 1

  9. Degree of pollution: 2

  10. Mounting: Wall mounting

  11. Display: System-Monitoring for visualization of the systems, LED and background illumination

  12. Operation: 5 push buttons at the front cover.

  13. Accuracy of temperature measuring: ± 0.1oC

  14. Range of collector temperature measuring: -10oC ~220oC

  15. Range of tank temperature measuring: 0oC ~110oC

  16. Suitable power of pump: 6 pump possible to be connected  

  17. Suitable power of HK (backup heating): 1pc ˂220W .

  18. Inputs: 8 sensors,

    2pcs*Pt1000 sensor (≤500oC) for collector (silicon cable≤280oC),

    6pcs*NTC10K, B3950 sensor (≤ 135oC) for tank, (PVC cable ≤105oC),

    @1* Grundfos Direct Sensor (VFS type)
    @1* Rotary blade electronic flowmeter (FRT)
     

  19. Outputs: 6 relays, for circulation pump and backup heating

    3*Electronmagnetic relay, Max.current 1A

    3*Semiconductor relay, Max.current 1A

    @1*Potential-free extra-low voltage relay(on/off signal)

    @3*PWM variable frequency output(switchable 0-10v)

  20. Ambient temperature: -10oC ~ 50oC. 


 Delivery list

  1. 1 * SR658 controller

  2. 1 * user manual

  3. 2 * screen and expansion

  4. 2 * P1000 temperature sensor (φ6*50mm, cable length 1.5meter)

  5. 4 * NTC10K temperature sensor (φ6*50mm, cable length 3meter)

  6. 1 * clamp bag

Note: TF (Micro SD) isn’t included in the delivery list


Terminal connection

5631570784510519.jpg

  1. T0~T1: PT1000 temperature sensor, for measuring the temperature of collector

  2. T2~T7: NTC10K, B=3950 temperature sensor, for measuring temperature of tank and pipe

  3. PWM1, PWM2, PWM3: Signal ports for high efficiency pump, detailed connection see below

  4. picture

  5. HK-A, HK-B: Dry connection on/off signal ports, (HK and HR simultaneously open or close,

  6. for boiler heating control)

  7. Communication port 485: ELA485, for remote control communication( function not available

  8. now)

  9. FRT: For Rotary blade electronic flowmeter

  10. VFS: For Grundfos flowmeter sensor

  11. Input Ports L, N: for power connection, L: live wire, N: zero wire, PEE: protective ground wire

  12. Output R1: Semiconductor relays (SCR), designed for pump speed control, Max. Current: 1A

  13. Output R2: Semiconductor relays (SCR), designed for pump speed control, Max. Current: 1A

  14. Output R3: Semiconductor relays (SCR), designed for pump speed control, Max. Current: 1A

  15. Output R4: Electromagnetic relays, designed for pump or 3-ways electromagnetic valve, Max. Current: 1A 

  16. Output R5: Electromagnetic relays, designed for pump or 3-ways electromagnetic valve, Max. Current: 1A

  17. Output HR: Electromagnetic relays, designed for back-up heating device, Max. Current: 1A


Main functions:

  1. DATE---Date setting

  2. Light---Display lightness adjustable

  3. Timed heat---backup heating

  4. Circle---Hot water circulation

  5. Sys—Application programmer

  6. LOAD---Setup Loading tank1

  7. LOAD2--- Setup Loading tank2

  8. COL---Collector1

  9. COL2---Collector2

  10. PUMP---Pump control mode

  11. LLOGI---Tank loading logic

  12. COOL---Cooling function

  13. HEATX---Thermal energy transfer between tanks.

  14. RPH---Preheat heating return function

  15. AUX---Auxiliary function

  16. MAN---Manual mode

  17. BLPR---Blocking protection function

  18. OTDIS---Thermal disinfection function

  19. OPARR---Parallel relay function

  20. OHQM---Thermal energy measurement

  21. GFDS---Registration of Grundfos sensor

  22. UNIT---C-F unit switch

  23. OSDS---SD card

  24. REST---reset

  25. PASS--- password set

  26. Firmware update

  27. Holiday function

  28. Screen Protection

  29. Trouble Protection

  30. Trouble Checking

1.JPG

2.JPG

3.JPG

5.JPG

1-1FZ9142557-50.jpg


Similar Product Recommend