SR208C Solar Hot Water Controller

Model
SR208C
Nature of the Manufacturer
Manufacturer
Product Category
Split Pressure Series Controller
Place of Origin
City, Province
Overview
SR208C Solar Hot Water Controller
Product Details

INTRODUCE 


For below solar hot water system  :

  1. Split type high pressure system 

  2. Split type Low / Non pressure system + Assistant tank with float ball


APPLICATIONS CAPACITY 

  1. Max.number of collectors:1

  2. Max.number of storage tanks:1

  3. Max.number of relays:2

  4. Max.number of sensors:3

  5. Max.number of visualization application system:1


TECHNICAL DATA

  1. Size of Controller:178mm x120mm x43mm

  2. Power supply:AC100-240V,50-60Hz. .  

  3. Power consumption: < 2.5W

  4. Accuracy of temperature measuring: ± 0.1oC

  5. Range of collector temperature measuring: -10oC ~220oC

  6. Range of tank temperature measuring: 0oC ~110oC

  7. Conventional/High efficiency pump both available on

  8. Inputs: 

    1pcs*Pt1000 sensor (≤500oC) for collector (silicon cable≤280oC),

    2pcs*NTC10K, B3950 sensor (≤ 135oC) for tank, (PVC cable ≤105oC),

    # 1pcs * 485 communication port(Optional)

  9. Outputs: 

    R1 : For conventional/High efficinecy circulation pump ,  maximum current 1A .  

    HR : For backup heating ,maximum current 2A , It can connect with SR802 high power relay .

    # PWM :  variable frequency output (on/off switchable, 0-10V)

  10. Ambient temperature:-10oC ~ 50oC.

  11. Water proof grade: IP41


Delivery list

  1. 1 * SR208C controller

  2. 1 * accessory bag

  3. 1 * user manual

  4. 1 * PT1000 temperature sensor (φ6*50mm,cable length 1.5meter)

  5. 2 * NTC10K temperature sensor (φ6*50mm,cable length 3meter)

8501569829327563.jpg


1861569829369247.jpg

Main functions:

  1. CLK time setup 

  2. AH Afterheating/thermostat

  3. PWDPassword protection

  4. LOAD Tank heating

  5. OCEM Collector emergency shutdown

  6. OCCO Collector cooling

  7. OCMI  Collector minimum temperature

  8. OCFR Antifreeze

  9. OTCO Tube collector

  10. PUMP Pump control mode

  11. OSYC System cooling

  12. OSTC Tank cooling

  13. MAN Manual mode

  14. BLPR Blocking protection

  15. OTDI Thermal Disinfection

  16. UNIT C-F switch

  17. BEEP beeper fault warning

  18. Memory function

  19. Screen protection

  20. Trouble checking


1-1FZ9123G5-50.jpg

1-1FZ9123G5-51.jpg

Similar Product Recommend