Class III Biosafety Cabinet is totally enclosed and gas-tight, it also can meet the requirement of operating Class I,II,III,IV pathogenic factor. It can be used in P3,P4 laboratory.
Product Details
Class III Biosafety Cabinet is totally enclosed and gas-tight with ULPA filtered supply and exhaust air. Work is performed with long-sleeved gloves. The cabinet is kept under negative pressure of at least 120Pa, and airflow is maintained by a dedicated exterior exhaust system. It can protect the operator, product and environment.
Advantage:
1.With memory function in case of power-failure.
2. UV lamp ensures work area sterilization effectively.
3.An angled cabinet front ensure an ergonomic working posture.
4.Exhaust air is double-filtered through high-quality ULPA filters with typical efficiency of 99.9995% for 0.12μmparticles.
Models:
Model
BSC-1100IIIX
BSC-1500IIIX
External Size(W*D*H)
1540*880*2000 mm
1790*880*2080 mm
Internal Size(W*D*H)
910*650*660 mm
1165*650*660 mm
Pass Box Size(W*D*H)
Internal Size:430*330*355mm
External Size:575*425*495mm
Gloves
One pair of 800mm butyl rubber gloves
Front Window
8 mm toughened glass, anti-ultraviolet radiation
Display
LCD display
Pre-filter
Polyester fiber, washable
Pressure
≥ negative120 Pa
ULPA Filter
Air supply filter: Efficiency 99.9995% at 0.12μm
First exhaust filter: Efficiency 99.9995% at 0.12μm
Second exhaust filter: Efficiency 99.9995% at 0.12μm
Noise
≤67dB
Alarm
Audio and visual alarm, abnormal pressure; filter replacement
Work Zone Material
304 stainless steel
Illumination
≥ 1000 lux
Consumption
1200W
1300W
LED Lamp
12W*2
16W*2
UV Lamp
18W*2 ,8W*1
30W*2, 8W*1,
Emission of 253.7 nanometers for most efficient decontamination
Class III Biosafety Cabinet is totally enclosed and gas-tight with ULPA filtered supply and exhaust air. Work is performed with long-sleeved gloves. The cabinet is kept under negative pressure of at least 120Pa, and airflow is maintained by a dedicated exterior exhaust system. It can protect the operator, product and environment.
Advantage:
1.With memory function in case of power-failure.
2. UV lamp ensures work area sterilization effectively.
3.An angled cabinet front ensure an ergonomic working posture.
4.Exhaust air is double-filtered through high-quality ULPA filters with typical efficiency of 99.9995% for 0.12μmparticles.
Models:
Model
BSC-1100IIIX
BSC-1500IIIX
External Size(W*D*H)
1540*880*2000 mm
1790*880*2080 mm
Internal Size(W*D*H)
910*650*660 mm
1165*650*660 mm
Pass Box Size(W*D*H)
Internal Size:430*330*355mm
External Size:575*425*495mm
Gloves
One pair of 800mm butyl rubber gloves
Front Window
8 mm toughened glass, anti-ultraviolet radiation
Display
LCD display
Pre-filter
Polyester fiber, washable
Pressure
≥ negative120 Pa
ULPA Filter
Air supply filter: Efficiency 99.9995% at 0.12μm
First exhaust filter: Efficiency 99.9995% at 0.12μm
Second exhaust filter: Efficiency 99.9995% at 0.12μm
Noise
≤67dB
Alarm
Audio and visual alarm, abnormal pressure; filter replacement
Work Zone Material
304 stainless steel
Illumination
≥ 1000 lux
Consumption
1200W
1300W
LED Lamp
12W*2
16W*2
UV Lamp
18W*2 ,8W*1
30W*2, 8W*1,
Emission of 253.7 nanometers for most efficient decontamination