Introduction: Monkeypox is a zoonotic disease caused by the monkeypox virus, which can be transmitted from animals to humans as well as from human to human. Monkeypox symptoms often include fever, severe headache, muscle aches, swollen lymph nodes, skin lesions, and more. According to the World Health Organization, more than 50 countries and regions around the world have reported confirmed cases of monkeypox. There is currently no cure for monkeypox, and the World Health Organization urges countries to strengthen ......
Product Details
Application:
It is applied to the monitoring and auxiliary diagnosis of monkeypox virus. The application scenarios mainly include hospitals, CDC, scientific research institutions, and third-party medical testing laboratories recognized by health administrative agencies.
Feature:
Internal Control: the kit contains Internal Control, which is involved in nucleic acid extraction and PCR detection to avoid false negative results
Control:Both negative and positive control in the kit need to be extracted for environmental monitoring and quality control of PCR detection reagents
High Sensitivity: The detection limitation is 200 copies/ml
High specificity: No cross reaction with other pathogens
Fast Speed: Nucleic acid extraction completed within 10 minutes,and the PCR amplification time is less than 1 hour
Certificate: CE declaration of conformity
Technical Parameter:
Product Name
Monkeypox Virus (MPV) Nucleic Acid Detection Kit
(PCR-Fluorescence Probe Method)
Detection Principle
Fluorescence PCR
Detection Target
Monkeypox Virus F3L gene
Sample Types
Serum or lesion exudate samples
Applicable Instruments
ABI7500、LEIA-X4、FQD-96A, etc
Storage
-20±5℃
Valid Period
12 Months
Reaction volume
25ul
Detection Time
<60 min
Detection Limit
200 copies/ml
Packing Specification
24T/box or 48T/box or 96T/box;
90 boxes/carton
Packet Size(L*W*H)
500*500*500mm
Gross Weight
24kg
Application:
It is applied to the monitoring and auxiliary diagnosis of monkeypox virus. The application scenarios mainly include hospitals, CDC, scientific research institutions, and third-party medical testing laboratories recognized by health administrative agencies.
Feature:
Internal Control: the kit contains Internal Control, which is involved in nucleic acid extraction and PCR detection to avoid false negative results
Control:Both negative and positive control in the kit need to be extracted for environmental monitoring and quality control of PCR detection reagents
High Sensitivity: The detection limitation is 200 copies/ml
High specificity: No cross reaction with other pathogens
Fast Speed: Nucleic acid extraction completed within 10 minutes,and the PCR amplification time is less than 1 hour