Thermal Cycler

Model
Nature of the Manufacturer
Manufacturer
Product Category
Life Science Instrument
Place of Origin
City, Province
Overview
Product Details
Feature
gradeInhibit Nonspecific Amplification

The experienced soft design inhibits the nonspecific amplification of reagents. In practice, if the PCR reagent is put into the block immediately before the hot lid temperature reaches the set value, the reagent in the block will also heating-up with hot lid. Here, the reagent in block will begin to react slowly. But this is not the desired, that is, nonspecific amplification. What to do? during the hot lid warming up, the block is cooled to 10℃ until the hot lid temperature get set value before running the cycle program.

gradeInhibit Nonspecific AmplificationAdjustable Ramp Rate

Actually, not all PCR experiments require the fastest ramp rate. Some PCR reactions require fixed heating rate or cooling rate to ensure the result of PCR reaction. After long-term technical accumulation and algorithm optimization, ETC811 provides a nearly perfect linear temperature control curve.

gradeInhibit Nonspecific Amplification Prevent Evaporation

In order to speed up the temperature balance between block and reagent and shorten the reaction time of PCR, the control mode of overheating block temperature is often used in the temperature control algorithm of PCR. However, for small-volume reaction of PCR, excessive overheating will make reagent temperature close to boiling point, which will cause reagent evaporation or even drying, leading to the abandonment of previous work. With the accumulation of temperature control technology for many years, the reagent of ETC811 PCR will not evaporate even in a small volume of 5-15ul, so as to ensure the success of the experiment.

gradeInhibit Nonspecific AmplificationTemperature Synchronization

When gradient function is used to optimize the PCR reaction conditions, there are two variables, time and temperature. When the temperature gradient is set, we tend to focus only on the effect of temperature on the PCR reaction. In fact, the time of arrival of temperature is different for each column well. This raises the question: is the result of optimization a function of temperature or time? ETC811 uses a special temperature control algorithm to solve this problem well. By eliminating the time variable, the gradient PCR optimization experiment is only related to temperature, which greatly improves the certainty of the test results.

gradeInhibit Nonspecific AmplificationEasy to Pressurize and Lock.

● Press and lock simultaneously
● Damped cover shaft can be stopped whenever you want
● Adaptable to different tubes (except full skirt)

gradeInhibit Nonspecific AmplificationBuilt in Engineering Mode

● Press and lock simultaneously
● Damped cover shaft can be stopped whenever you want
● Adaptable to different tubes (except full skirt)

gradeOptional module model