Main Characteristics
1、IGBT solid-state inverter,high efficient,energy saving and good quality.
2、Hundred Percent Rated Duty Cycle design,can work 24hours continuously.
3、Phase-Locked technology,automatically tracking frequency.
4、Perfect self-protection function,high reliability,simple installation,convenient operation.
5、Can control the heating temperature remotely and automatically by extra Infrared Thermometer,improve the heating quality and reduce human operation.
6、It is energy saving and environmental protection heating way which can replace the other common heating method:such as oxygen-acetylene furnace,coke furnace,salt bath heaters, gas heaters, etc.
Parameter
Type | KIU-30AB | KIU-50AB | KIU-65AB | KIU-80AB | KIU-100AB | KIU-120AB | KIU-160AB | KIU-200AB | KIU-300AB |
Max Fluctuating Power | 30KVA | 50KVA | 65KVA | 80KVA | 100KVA | 120KVA | 120KVA | 200KVA | 300KVA |
Fluctuating Frequency | 10-40KHZ | 10-30KHZ | 10-30KHZ | 10-30KHZ | 10-30KHZ | 10-30KHZ | 10-30KHZ | 10-30KHZ | 10-30KHZ |
Heating Current | 100-1600A | 100-2400A | 100-3200A | 100-4000A | 100-4600A | 100-5600A | 100-6500A | 100-7500A | 100-10000A |
Input Voltage | 3-Phase,380V, 50HZ-60HZ | 3-Phase,380V, 50HZ-60HZ | 3-Phase,380V, 50HZ-60HZ | 3-Phase,380V, 50HZ-60HZ | 3-Phase,380V, 50HZ-60HZ | 3-Phase,380V, 50HZ-60HZ | 3-Phase,380V, 50HZ-60HZ | 3-Phase,380V, 50HZ-60HZ | 3-Phase,380V, 50HZ-60HZ |
The Flow Rate of Cooling Water | 0.2Mpa 26L/Min | 0.2Mpa 26L/Min | 0.2Mpa 26L/Min | 0.2Mpa 32L/Min | 0.2Mpa 32L/Min | 0.2Mpa 38L/Min | 0.2Mpa 38L/Min | 0.2Mpa 38L/Min | 0.2Mpa 38L/Min |
Water Temperature Protection Point | 40℃ | 40℃ | 40℃ | 40℃ | 40℃ | 40℃ | 40℃ | 40℃ | 40℃ |
Net Weight(Kg) | Main Part:30Kg Transformer Part:25Kg | Main Part:35Kg Transformer Part:30Kg | Main Part:40Kg Transformer Part:45Kg | Main Part:50Kg Transformer Part:50Kg | Main Part:50Kg Transformer Part:55Kg | Main Part:70Kg Transformer Part:90Kg | Main Part:90Kg Transformer Part:100Kg | Main Part:90Kg Transformer Part:100Kg | Main Part:100Kg Transformer Part:120Kg |
Dimension (cmL×cmW×cmH) | Main Part 500*400*700mm Transformer Part 360*330*360mm | Main Part 500*400*900mm Transformer Part 400*330*360mm | Main Part 500*400*900mm Transformer Part 400*330*360mm | Main Part 740*560*1000mm Transformer Part 530*400*480mm | Main Part 740*560*1000mm Transformer Part 530*400*480mm | Main Part 660*600*1680mm Transformer Part 620*430*470mm | Main Part 660*700*1680mm Transformer Part 470mm | Main Part 660*700*1680mm Transformer Part 630*430*470mm | Main Part 700*720*1680mm Transformer Part 660*430*470mm |