0~5V(10V)0~5V&0~10V is adjustable by switch(view the pictures).
Rw-st01a 0-5V 0-10V 4-20mA Load Cell sensor Amplifier Transmitter strain gauge transducer
1.0~5V(10V)&4~20mA can output at the same time;0~5V&0~10V is adjustable by switch(view the pictures).
2. The built-in precision amplifier circuit, high precision, low temperature drift, long-term stability;
3. Current and voltage output offer at the same time, choose through the terminal blocks;
4. A wide range of power-supply modes
5. Input overvoltage and overcurrent protection, output short circuit protection;
6. Load capacity is strong, use with junction box, it can connect with more than one sensor;
7. Apply to weighing, pull pressure, torque, etc. Various kinds of strain bridge type sensor
8. The shell and cable connector waterproof design, tightness is good, applicable to various kinds of severe environment;
9. Load capacity:87Ω(can connect with 4pcs of 350Ω load cell sensor in parallel)

Parameter
| Input signal | Full bridge strain gauge/Load cell | Note |
Bridge resistor | <2KΩ |
|
Sensitivity | 1.5~2.1mV/V |
|
Excitation voltage | 5V DC |
|
Excitation current | <100mA@12V supply <50mA@24V supply |
|
Power supply | 12~26V DC vs. 0~5V output & 4~20mA output 18~26V DC vs. 0~10V & 4~20mA output |
|
Linear | 0.3% |
|
Temperature coefficient | 50ppm@10~30 degree, 100ppm full work temperature range |
|
Operating temperature | 0~50 degree |
|
Weight | 90g |
|
Dimension | 115mm×80mm×35mm(bolt center: 97mm) |
|
Wiring
| Terminal No. | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 |
Define | ToLoad cell | Power supply & Output |
EXC+ | SIG+ | SIG- | EXC- | Shield | 12~26V DC | Iout | Vout | Common. | Shield |