In the process of fire assay, the waste gas containing lead will be produced, which is harmful to human body and must be filtered before being discharged into the external environment.
Product Details
Fire Assay Lab Exhaust Removal System
In the process of fire assay, the waste gas containing lead will be produced, which is harmful to human body and must be filtered before being discharged into the external environment.
Our company has developed a set of exhaust removal system for fire assay laboratory, including pulse filter cartridge dust collector, centrifugal fan, furnace hood and pipe.
Cartridge filter adopts one kind of micro filter which includes activated carbon adsorbent material. So it can filter 99.9% submicron particle.
● Advanced Function: Adoption of the latest German dedusting technology which is different from traditional ventilation exhaust, water filter and bag filter and can collecting and even recycling of small dust.
● Superior Quality: All main parts are made from imported material, which offers incomparable filtrability and ventilation compared to common material. Every square meter can handle minimum 0.1 micron dust while flow rate can reach 235 m3/h. Filtration efficiency is greatly increased because of folding type structure by comparing with bag filter .
● Intelligent Control: Famous brand microcomputer control combines with pneumatic control system to ensure machine to work effectively and stably, which is more stable and intelligent and easier to operate and control.
● Intelligent Test: Intelligent negative pressure detection system offers automatic cleaning when filter element is blocked and negative pressure in box increases.
● Applicability: the use of advanced manufacturing technology, the volume is the same bag type collector filtration area 1/3, convenient transportation, and can be a good place for a variety of installation, stacked shape design, blue and white contrast color spray, beautiful and practical.
● Customized to different site needs.
1. Mix the fire assay sample and flux in a plastic bag.
2. Put the sample plastic bag into a clean fire test crucible. It is recommended to use the crucible mixer produced by our company, which can mix 25 or 50 samples in batches.
3. Load the crucible containing the sample and flux into the furnace heated to 1100°C.
4. After 50 minutes, the sample is taken out of the furnace and poured into the mold.
5. After cooling, knock and separate the glass and the lead buckle.
6. After the lead button is weighed and recorded, put it into the cupel.
7. Put the cupel containing the lead button into the cupellation furnace that has been heated to 950°C.
8. Check after 1h and take out the cupel containing the gold and silver bullion.
9. After cooling, pick up the gold and silver pellets into the glass test tube/rack.
10. Move the test tube/rack to the acid dissolution chamber for further testing.