Welcome Customer !

Membership

Jiuyin Science and Technology Chengdu Co., Ltd.
Free Member ·1YRS
ChengDou,SiChuan
Manufacturer

Main Products: Oxygen Nitrogen Analyzer (Oxygen Nitrogen Hydrogen Analyzer)|Automobile Exhaust Gas Analyzer

Xwboo>Products

Jiuyin Science and Technology Chengdu Co., Ltd.Free·1YRS

  • E-mail

    sales@meas-elec.com,service@meas-elec.com

  • Phone

    028-85044052/028-85044053

  • Address

    4th floor, unit 1, building 4, District D, West Zhigu, 66, Wuxing 4th Road, Wuhou District, Chengdu City, Sichuan Province

Contact Now

CX600 Gas Monitor

Model
Nature of the Manufacturer
Manufacturer
Product Category
Explosion-proof oxygen analyzer
Place of Origin
City, Province
Overview
CX600 Gas Monitor
Product Details

    Measurement Range: please refer to the chart (measuring media are selectable)

    Display Mode: segment code display

    Measurement Accuracy: ≤±3%FS

    Repeatability: <±3%FS

    Response Time: T90≤30S

    Output Interface: 4-20mA.DC (Non-isolated output, load resistance<1KΩ)

    1 way of programmable alarm output (Dry contact type, maximum load 220VAC/2A)

    Light and sound alarm output

    Alarm Alert: Super bright and loud alarm alert

    Power Supply: DC24V±10%,5W

    Environment Temperature: -10℃~+50℃

    Storage Environment Humidity: <90%RH, non-condensing

    Operation Environment Humidity: <99%RH, non-condensing

    Sampling Mode: Free diffusion (other mode can be customized)

    Sample Gas Pressure: Relative pressure ±5kPa, stable pressure

    Size: 204mm×195mm×92.5mm(H×W×D)

    Explosion-Proof Level: Exd IIC T6 Gb

    Certificate Number: CNEx19.2161X

    Installation Method: wall mounting

    Measurement Range:

    Measured Gas

    Measured Principle

    Measured Range

    Resolution

    CO

    catalytic combustion sensor

    0~1000PPm

    1PPm

    H2

    fuel cell

    0~30000PPm

    1PPm

    CH4

    catalytic combustion sensor

    0~99%LEL

    1%LEL

    HCL

    fuel cell

    0~20PPm

    0.1PPm

    C2H2

    catalytic combustion sensor

    0~99%LEL

    1%LEL


    a. The segment code display mode is clear and intuitive, and the operation of the instrument is easy and convenient;

    b. The original imported sensor has a rapid response speed, high accuracy, excellent linearity, long calibration cycle, stable performance, and its sensor can be changed when reaches its service life;

    c. Functional modules can be combined freely, which means the gas monitor with different functions can be formed. Relay output, sound and light alarm output, error state indication, infrared remote-control function can be equipped;

    d. The alarm limit of the sound and light alarm can be adjusted, and the operation is easy and convenient;

    e. In explosion-proof occasions, the menu can be set by isolated-type magnetic pen, which is convenient for on-site operation;

    f. Automatic temperature compensation could eliminate the impact of environment temperature changes on the measured value;

    g. The instrument allows multi-point fractional liner calibration, meeting the need for an accurate measurement of concentration among the full range;

    h. Explosion-proof level is Exd IIC T6 Gb.



    It can be applied in the gas concentration measurement in occasions which require the explosion-proof level to be Exd IIC T6, and it has been widely applied in petroleum industry, chemical industry, metallurgy, refining, gas distribution, biochemical medicine and other industries.



                            