IP65 30VDC Flow Pressure Transducers For Orifice Plate
IP65 30VDC Flow Pressure Transducers For Orifice Plate
Description Maximum Line Pressure: | 10 PSI | Overpressure: | 10 PSI In Positive Or Negative Direction |
---|
Case: | IP65 Die-cast Aluminum Enclosure | Electrical Connection: | Screw Terminal Strip Inside Of Case |
---|
High Light: | IP65 Flow Pressure Transducers, 30VDC Flow Pressure Transducers, 30VDC Flow Through Pressure Sensor |
PPM-WCY68-P500A Orifice Plate Flow Measure Pressure Transducer
Product Introduction:
pressure transducers sense gauge(static) or differential pressure and convert this pressure difference to a proportional current or voltage output. The 268 series is offered with a high level analog 0 to 5 VDC, 0 to 10 VDC or 4-20mA output. The 268MR offers multi-range capability and field configurable output. The Model 268 is packaged in a die-cast aluminum enclosure that is specifically designed for IP65 service to withstand environmental effects. Used in Building Energy Management Systems, the 268 and 268MR pressure transducers are available for air pressure ranges as low as 0.1 in W.C. (25 Pa) full scale to 100 in. W.C. (25 kPa) full scale. Static accuracy is ±1% full scale in normal ambient temperature environments. The 268 series utilizes an improved all stainless steel micro-tig welded sensor, which is enclosed in a welded stainless steel body. The tensioned stainless steel diaphragm and insulated stainless steel electrode, positioned close to the diaphragm, form a variable capacitor. As the pressure increases or decreases, the capacitance changes. The change in capacitance is detected and converted to a linear DC electrical signal by Setra’s unique electronic circuit. The micro-tig welded tension sensor allows up to 10 psi overpressure(in either direction), with no damage to the unit.The improved sensor design also allows the Model 268MR version to have 6 field selectable pressure ranges (bi-directional and unidirectional) in one unit. The simple flip of a dip switch enables the user to easily field calibrate the unit with minimal effort. Explosion- proof units are approved for ia II CT4.
Applications :
●Power Plant
●Energy Management Systems
●Orifice Plate Flow Measure
●Oven Pressurization and Furnace Draft Controls
Technical Parameters :
Parameter Accuracy RSS* (at constant temp.) | Standard ±1.0%FS | Optional ±0.4%FS | Optional ±0.25%FS |
Non-Linearity (BFSL) | ±0.98%FS | ±0.33%FS | ±0.20%FS |
Hysteresis | ±0.20%FS | ±0.20%FS | ±0.20%FS |
Non-Repeatability | ±0.05%FS | ±0.05%FS | ±0.05%FS |
Thermal Effects** Compensated Range °F(°C) | +40 to +150 (+5 to +65) | | |
Zero/Span Shift %FS/ °F(°C) | ±0.033 (±0.06) | | |
Maximum Line Pressure | 10 PSI | | |
Overpressure | 10 PSI in Positive or Negative Direction | | |
Warm-up Shift | ±0.1% FS Total | | |
Position Effect*** | Range | Zero Offset (%FS/g) | |
0 To 25Pa | 2.1 | |
0 To 250Pa | 0.22 | |
0 To 1250Pa | 0.14 | |
0 To 7500Pa | 0.06 | |
Physical Description |
Case | IP65 die-cast aluminum enclosure | | |
Electrical Connection | Screw Terminal Strip Inside of Case | | |
Electrical Termination | PG-9 | | |
Zero and Span Adjustment | Accessible Inside of Case | | |
Pressure Fittings | 3/16" O.D. Barbed Brass for 1/4" Push-On Tubing (Standard) | | |
Mounting | 2 Mounting Tabs with 0.18" Holes | | |
Weight (approx.) | 348 grams | | |
Pressure Media | Typically Air or Similar Non-Conducting Gases. | | |
Environmental Data Temperature Operating* °F (°C) Storage °F (°C) | 0 to +150 (-18 to +65) -65 to +180 (-54 to +82) | | |
Electrical Data (Current) |
Circuit | 2-Wire | | |
Output* | 4 to 20 mA** | | |
Bidirectional Output at Zero | 12 mA | | |
External Load | 0 to 800 Ohms | | |
Minimum loop supply voltage | (VDC) = 9 + 0.02 x (Resistance of receiver plus line) | | |
Maximum loop supply voltage | (VDC) = 30 + 0.004 x (Resistance of receiver plus line) | | |
Re-Ranging (268MR only) | 4 Position Dip Switches (located inside case) | | |
Dimensions in mm :