E-mail
manger@vikingdetector.com
- Phone
-
Address
Room 301, No.23, Machong Avenue, Machong Town, Dongguan City, Guangdong Province
Membership
Help
DONGGUAN VIKING TECHNOLOGY CO;LTDFree·1YRS
manger@vikingdetector.com
Room 301, No.23, Machong Avenue, Machong Town, Dongguan City, Guangdong Province

Tunnel Size: | 500(W)×300(H)mm |
Conveyor Speed: | 0.22 m/s |
Conveyor Max Load | 120 kg |
Single inspection dosage: | < 1.5µGy |
Wire Resolution: | 0.1mm metal line |
Steel Penetration: | 8MM armor plate |
Film Safety: | For ISO 1600 |
Maximum leakage radiation: | <0.3µGY/H |
Cost effective
World class image quality
High-end image capture, display, and archival
Wire Resolution for 38 AWG
Material discrimination based on atomic number signature
Based on atomic number signatures, 3 and 6 colors
Threat Image Projection
Multi-energy colour: Display organic material or inorganic for orange, and display mixtures for green
High energy/low energie: toggle to switch to display both energy types, high energy for metal etc. and low energy for nonmetallic
Auxiliary functions for drugs and explosives: These help detect dangerous material, such as explosives and drugs.
Audible and visible alarms: sound and sight signals to indicate compliance with conditions
Vertically Upward
Tube Current: 0.4~0.5MA(adjustable)
Anode Voltage (adjustable: 80 KV)
Angle: 60deg
Generator cooling/working period Sealed oil bath and forced air/99%
X-ray sensor: l type photo-diode array detector, 12bit
Monitor: High Resolution 17in Color LCD Display
Color quality: 24 bit real colors
Edge enhancement: A contour edge with an object is made more distinct
Super image enhancement: image detail is more distinct
High penetration strength display: To display objects with high absorbtivity, increase the brightness of the dark areas in the image.
Displays with low penetration strength: to increase contrast with low absorbtivity masses (easy to penetrate), in order to clearly display them
Magnifier: function for partial enlargement
Brightening/dimming Image: Increase brightness/decrease image brightness
Image restoration: This restores the image to its initial state at the time it was taken.
Image storing in real time: store any image and make it available for processing in operation status
X ray machine OPERATING ENVIRONMENT:
Temperature of Storage: -20ºC to 60ºC
Operating Temperature: 0ºC to 45ºC
Relative Humidity:20 to 95% non-condensing
System Power: 220 VAC (±10%) 50±3HZ
Power wastage:1.0 KW (Max)
Noise:<65D