mccb circuit breaker CATM1

Model
Nature of the Manufacturer
Manufacturer
Product Category
Place of Origin
City, Province
Overview
Categories MCCB Brand Kayal Model @Model["xinghao"] FOB Port Ningbo/Shanghai Terms of Payment Western Union,T/T,Paypal Update 2021/04/02
Product Details

DC circuit breakers are mainly used for overload and short circuit protection of distributed power and protection circuits and power supply equipment in DC systems with rated insulation voltage of 1600V, rated working voltage of DC 1500V and below, and rated current of 250A and below.


Normal working environment
1. The ambient air temperature is -5 °C - +40 °C.
2. The altitude of the installation site does not exceed 2000m.
3. The relative humidity of the air at the installation site does not exceed 50% at a maximum temperature of +40 ° C, and may have a relatively high relative humidity at a lower temperature, for example, 90% at 20 ° C. Special measures should be taken for condensation that occasionally occurs due to temperature changes.
4. The pollution level is level 2.
5. The main circuit installation category of the circuit breaker is III, and the other auxiliary circuit and control circuit installation categories are II.
6. The circuit breaker is suitable for electromagnetic environment A.
7. The circuit breaker shall be installed in a place where there is no danger of explosion and no conductive dust, no enough corrosion metal and damage to insulation.
8. The circuit breaker should be installed in a place where there is no rain or snow.
9. Storage conditions: ambient air temperature -40 ° C - + 70 ° C.

model KATM1-250
Leakage circuit breaker rated voltage Ue(V) DC1500
Rated insulation voltage Ui(V) 1600
Rated impulse withstand voltage Uimp(kV) 12
Rated current In(A) 100/125/160/180/200/225/250
Series 2
Rated ultimate short-circuit segmentation capability Icu(kV) 15
Rated operating short-circuit breaking capacity Ics(kA) 15
Electrical lifeMechanical maintenance7000
 Electrical life1000
Type of protectionDistribution protection√
 Motor protection√
Tripping methodThermal magnetic protection√
 Single magnetic protection√
Installation methodFixed board front wiring√
 Fixed board rear wiring√
Product accessoriesUndervoltage release√
 Shunt release√
 Alarm contact√
 Auxiliary contact (one open and one closed)√
 Auxiliary contact (two open and two closed)√
 Expansion terminal√
 AC operation CD1√
 AC and DC General Electric Exercise CD2√
 Round direct hand exercise√
 Square direct hand exercise√
 Round extended hand exercise√
 Square extension hand exercise√
 Phase spacer√
Attachment installation Yes
Isolation function Yes
Use category Class A
Installation size 35*161*Φ5
Size - fixed front connection (width * height * length) 200*135*86

catm1 5

Molded Case Circuit Breaker (MCCB)