They are normally used in connecting signaling and control units in industry, in railways, in traffic signals, in thermopower and hydropower stations.
Product Details
Application For supervisory electrical equipment, station control circuits. Suitable for indoor and outdoor installation in wet or dry locations, in conduit, duct, trench and cable tray. With metallic armour, the cable is suitable for installation in areas where special mechanical protection is required.
Applicable Standard IEC 60228
IEC 60227
Cable Construction Conductor Concentric stranded annealed copper Optional : Flexible or solid annealed copper
Conductor Size 1.5~-10 mm²
Insulation PVC (Polyvinyl Chloride)
Screen Copper Wire Braided
Inner sheath PVC (Polyvinyl Chloride)
Armor Galvanized Steel Tape
Sheath Flame retardant PVC (Polyvinyl Chloride)
Dimension Characteristics
Section
Conductor Class
Insulation Thickness
Screen Wire Diameter
Armour Thickness
Sheath Thickness
Overall Diameter
Cable Weight
No.xmm2
mm
mm
mm
mm
mm
kg/km
450/750 V
0.6/1 kV
450/750 V
0.6/1 kV
450/750 V
0.6/1 kV
450/750 V
0.6/1 kV
2x0.75
1
0.6
0.8
0.15
2x0.2
1.5
1.8
11.7
13.1
211
259
2x1
1
0.6
0.8
0.15
2x0.2
1.5
1.8
12.1
13.5
226
275
2x1.5
1
0.7
0.8
0.15
2x0.2
1.5
1.8
13.0
14.0
262
300
2x2.5
1
0.8
0.8
0.15
2x0.2
1.5
1.8
14.4
15.0
322
349
2x4
1
0.8
1.0
0.20
2x0.2
1.5
1.8
15.6
17.0
394
455
2x6
1
0.8
1.0
0.20
2x0.2
1.5
1.8
16.7
18.1
466
530
3x0.75
1
0.6
0.8
0.15
2x0.2
1.5
1.8
12.1
13.5
230
282
3x1
1
0.6
0.8
0.15
2x0.2
1.5
1.8
12.5
13.9
248
302
3x1.5
1
0.7
0.8
0.15
2x0.2
1.5
1.8
13.5
14.5
292
333
3x2.5
1
0.8
0.8
0.15
2x0.2
1.5
1.8
14.9
15.5
367
395
3x4
1
0.8
1.0
0.20
2x0.2
1.5
1.8
16.2
17.7
456
523
3x6
1
0.8
1.0
0.20
2x0.2
1.5
1.8
17.5
18.9
549
621
4x0.75
1
0.6
0.8
0.15
2x0.2
1.5
1.8
12.7
14.2
256
314
4x1
1
0.6
0.8
0.15
2x0.2
1.5
1.8
13.1
14.7
278
338
4x1.5
1
0.7
0.8
0.15
2x0.2
1.5
1.8
14.2
15.3
331
376
4x2.5
1
0.8
0.8
0.15
2x0.2
1.5
1.8
16.1
16.7
439
470
4x4
1
0.8
1.0
0.20
2x0.2
1.5
1.8
17.3
18.9
532
608
4x6
1
8.0
1.0
0.20
2x0.2
1.5
1.8
18.7
20.3
649
731
5x0.75
1
0.6
0.8
0.15
2x0.2
1.5
1.8
13.3
15.0
283
348
5x1
1
0.6
0.8
0.15
2x0.2
1.5
1.8
13.8
15.5
310
377
5x1.5
1
0.7
0.8
0.15
2x0.2
1.5
1.8
15.1
16.2
373
423
5x2.5
1
0.8
0.8
0.15
2x0.2
1.5
1.8
17.1
17.7
500
533
5x4
1
0.8
1.0
0.20
2x0.2
1.5
1.8
18.5
20.2
612
698
5x6
1
0.8
1.0
0.20
2x0.2
1.5
1.8
20.0
21.7
754
846
6x0.75
1
0.6
0.8
0.15
2x0.2
1.5
1.8
14.0
15.8
309
380
6x1
1
0.6
0.8
0.15
2x0.2
1.5
1.8
14.6
16.4
339
413
6x1.5
1
0.7
0.8
0.15
2x0.2
1.5
1.8
16.0
17.2
411
465
6x2.5
1
0.8
0.8
0.20
2x0.2
1.5
1.8
18.2
18.8
556
591
6x4
1
0.8
1.0
0.20
2x0.2
1.5
1.8
19.8
21.6
695
792
6x6
1
0.8
1.0
0.20
2x0.2
1.5
1.8
21.5
23.3
863
967
7x0.75
1
0.6
0.8
0.15
2x0.2
1.5
1.8
14.0
15.8
318
390
7x1
1
0.6
0.8
0.15
2x0.2
1.5
1.8
14.6
16.4
351
426
7x1.5
1
0.7
0.8
0.15
2x0.2
1.5
1.8
16.0
17.2
428
483
7x2.5
1
0.8
0.8
0.20
2x0.2
1.5
1.8
18.2
18.8
583
678
7x4
1
0.8
1.0
0.20
2x0.2
1.5
1.8
19.8
21.6
736
835
7x6
1
0.8
1.0
0.20
2x0.2
1.5
1.8
21.5
23.3
922
1028
Application For supervisory electrical equipment, station control circuits. Suitable for indoor and outdoor installation in wet or dry locations, in conduit, duct, trench and cable tray. With metallic armour, the cable is suitable for installation in areas where special mechanical protection is required.
Applicable Standard IEC 60228
IEC 60227
Cable Construction Conductor Concentric stranded annealed copper Optional : Flexible or solid annealed copper