The cable is intended for use in Photovoltaic Power Supply Systems: Indoor and/or outdoor, in industrial and agriculture fields.
Product Details
Application DC Cable H1Z2Z2-K acc. to EN 50618, are intended for use in Photovoltaic Power Supply Systems at nominal voltage rate up to 1,5/1,5kV DC.They are suitable for applications indoor and/or outdoor, in industrial and agriculture fields, in/at equipment with protective insulation (Protecting Class II), in explosion hazard areas.They may be installed fixed, freely suspended or free movable, in cable trays,conduits, on and in walls.DC Cable H1Z2Z2-K are suitable for direct burial where the corresponding guidelines for direct burial shall be considered.
Cable Construction Conductor: Electrolytic tinned copper, finely stranded class 5 in accordance with IEC 60228 Insulation: Halogen-free cross-linked compound Sheath: Halogen-free cross-linked, flame retardant compound Insulation & Sheath Color: Red or Black
Dimension characteristics
No. of Cores×Nominal Cross Section
No. of Stranding
Nominal Conductor Diameter
Nominal Insulation Thickness
Nominal Sheath Thickness
Nominal Overall Diamater
Nominal Weight
No.×mm2
-
mm
mm
mm
mm
kg/km
1×1.5
30/0.25
1.58
0.7
0.8
5.4
40
1×2.5
50/0.25
2.04
0.7
0.8
5.9
50
1×4.0
56/0.30
2.59
0.7
0.8
6.6
70
1×6.0
84/0.30
3.17
0.7
0.8
7.4
80
1×10
78/0.40
4.07
0.7
0.8
8.8
130
1×16
128/0.40
5.22
0.7
0.9
10.1
200
1×25
199/0.40
6.51
0.9
1
12.5
290
1×35
279/0.40
7.71
0.9
1.1
14
400
1×50
396/0.40
9
1
1.2
16.3
550
1×70
360/0.50
10.8
1.1
1.2
18.7
750
1×95
475/0.50
12.6
1.1
1.3
20.8
970
1×120
608/0.50
14.2
1.2
1.3
22.8
1220
1×150
756/0.50
15.8
1.4
1.4
25.5
1510
1×185
925/0.50
17.4
1.6
1.6
28.5
1850
1×240
1221/0.50
20.4
1.7
1.7
32.1
2400
Application DC Cable H1Z2Z2-K acc. to EN 50618, are intended for use in Photovoltaic Power Supply Systems at nominal voltage rate up to 1,5/1,5kV DC.They are suitable for applications indoor and/or outdoor, in industrial and agriculture fields, in/at equipment with protective insulation (Protecting Class II), in explosion hazard areas.They may be installed fixed, freely suspended or free movable, in cable trays,conduits, on and in walls.DC Cable H1Z2Z2-K are suitable for direct burial where the corresponding guidelines for direct burial shall be considered.
Cable Construction Conductor: Electrolytic tinned copper, finely stranded class 5 in accordance with IEC 60228 Insulation: Halogen-free cross-linked compound Sheath: Halogen-free cross-linked, flame retardant compound Insulation & Sheath Color: Red or Black