8.7/10kV (15kV) Aluminum Conductor XLPE Insulated Underground Medium Voltage Power Cable
Product Details
8.7/10kV (15kV) Aluminum Conductor XLPE Insulated Underground Medium Voltage Power Cable
Introduction
This cable is used to transmit power on the power transmission and distribution line of A.C.50Hz, rated voltage 35kV or lower. In comparison with PVC insulation cable, it boasts not only excellent electric character, mechanical character, heat and aging-resistant character, environmental stress-resistant character and chemical corrosion- resistant character, but simple structure, light weight, no restriction by laying drop, and high temperature allowance for long-term working as well.
Working conditions:
1)This maximum working temperature of the conductor is 90 0C;
During having a short (lasting less than 5 seconds) the maximum temperature of the cable conductor shall not be above 250 0C; Environment temperature should be no lower than 00C for laying the cable;
2)Bending radius allowance of the cable:
Single core cable: No steel tape cable 20D; Steel tape cable 15D
To be laid indoors, in tunnel, cable furrow or pipe, the cable couldn't bear mechanical force outside
YJY
YJLY
XLPE insulation PE sheath power cable
YJV22
YJLV22
XLPE insulation, steel tape armor, PVC sheath power cable
To be laid underground, the cable could bear certain mechanical force, but it couldn't bear great pulling force.
YJV23
YJLV23
XLPE insulation, steel tape armor, PE sheath power cable
YJV62
YJLV62
XLPE insulation, have no the magnetismsteel tape armor, PE sheath power cable
YJV32
YJLV32
XLPE insulation, thin steel-wire armor, PVC sheath power cable
Be applicable to the well, water inside and fall in the bad soil, the cable cans bear the equal dint outside the machine with pull the dint
.
YJV72
YJLV72
XLPE insulation, have no the magnetism thick steel-wire armor, PVC sheath power cable
YJV42
YJLV42
XLPE insulation, thick steel-wire armor, PVC sheath power cable
Be applicable to the well, underwater with the bottom of sea, the cable cans bear the bigger pressure with lead to pull the dint.
Hint Specially
The single-core magnetism material packs the cable is not suitable for to use for the AC power supply back track, the necessity hour eligibility uses the single-core 62 or 72 type pack the cable.
Disallow the cent to cross the magnetism piping mutually when single-core cable establish, the in order to prevent results in the descent that cable transport electric current ability.
Test Voltage and biggest Discharge capacity of cable
Rated Voltage
(kV)
3.6/6
6/6
6/10
8.7/10
8.7/15
12/20
18/30
21/35
26/35
Test Voltage
(kV)
6.23
10.38
15.05
20.76
31.14
36.33
44.98
Discharge capacity
(pC)
10
10
10
10
10
10
10
AC voltage test of cable
Rated Voltage
kV
0.6/1
1.8/3
3.6/6
3.6/10
6/6
6/10
8.7/10
8.7/15
12/20
18/30
21/35
26/35
Test VoltagekV
3.5
6.5
12.5
21
30.5
42
63
73.5
91
min
Test Time
5
5
5
5
5
5
5
5
5
Max. DC resistance of cable conductor at 20℃
Rated cross area(mm2)
0.5
0.75
1.0
1.5
2.5
4
6
10
Cu(Ω/km)
Non tinned
36.0
24.5
18.1
12.1
7.41
4.61
3.08
1.83
Tinned
36.7
24.8
18.2
12.2
7.56
4.70
3.11
1.84
Al (Ω/km)
/
/
/
18.1
12.1
7.41
4.61
3.08
Rated cross area(mm2)
16
25
35
50
70
95
120
150
Cu (Ω/km)
Non tinned
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
Tinned
1.16
0.734
0.529
0.391
0.270
0.195
0.154
0.126
Al (Ω/km)
1.91
1.20
0.868
0.641
0.443
0.320
0.253
0.206
Rated cross area(mm2)
185
240
300
400
500
630
800
1000
Cu (Ω/km)
Non tinned
0.0991
0.0754
0.0601
0.0470
0.0366
0.0283
0.0221
0.0176
Tinned
0.100
0.0762
0.0607
0.0475
0.0369
0.0286
0.0224
0.0177
Al ( Ω/km)
0.164
0.125
0.100
0.0778
0.0605
0.0469
0.0367
0.0291
Structure of power cable
8.7/10(12)kV、8.7/15(17.5)kV 1-core XLPE insulation PVC sheath power cable
Nominal Area
mm2
Non armored
Tape-armored
Wire-armored
Reference diameter
mm
Approximate weight
kg/km
Reference diameter
mm
Approximate weight
kg/km
Reference diameter
mm
Approximate weight
kg/km
YJV
YJLV
YJV62
YJLV62
YJV72
YJLV72
1*25
23.1
775
620
25.0
1063
884
28.7
1662
1483
1*35
24.1
900
683
26.0
1204
960
29.8
1828
1584
1*50
25.4
1080
770
27.3
1406
1064
31.2
2063
1721
1*70
27.0
1314
880
29.0
1672
1200
33.0
2371
1900
1*95
28.7
1601
1012
31.4
1980
1348
35.5
2971
2338
1*120
30.2
1881
1137
32.8
2278
1486
37.0
3315
2523
1*150
31.9
2213
1283
34.4
2631
1647
38.7
3721
2737
1*185
33.6
2590
1444
36.0
3026
1820
40.4
4168
2962
1*240
36.0
3173
1686
38.3
3647
2092
42.8
4864
3309
1*300
38.3
3801
1942
40.6
4312
2378
45.3
5605
3671
1*400
41.8
4831
2353
44.9
5400
2835
49.9
7250
4685
1*500
45.2
5889
2790
48.2
6518
3298
53.4
8510
5290
8.7/10(12)kV、8.7/15(17.5)kV 3-core XLPE insulation PVC sheath power cable
Nominal Area
mm2
Non armored
Tape-armored
Wire-armored
Reference diameter
mm
Approximate weight
kg/km
Reference diameter
mm
Approximate weight
kg/km
Reference diameter
mm
Approximate weight
kg/km
YJV
YJLV
YJV22
YJLV22
YJV32
YJLV32
3*25
47.7
2460
1988
52.5
3593
3121
55.7
5194
4722
3*35
49.9
2843
2192
54.9
4052
3401
58.1
5731
5080
3*50
52.9
3429
2499
58.1
4735
3805
61.3
6516
5586
3*70
56.7
4206
2905
61.9
5604
4303
65.2
7508
6207
3*95
60.4
5110
3343
66.0
6656
4889
69.1
8661
6894
3*120
63.6
5992
3761
69.4
7650
5419
72.6
9766
7535
3*150
67.3
7041
4252
73.1
8790
6001
76.2
11023
8234
3*185
70.9
8230
4790
76.9
10107
6667
81.5
13432
9992
3*240
76.1
10078
5616
82.3
12124
7662
86.8
15670
11208
3*300
81.2
12101
6524
88.8
15183
9606
92.1
18080
12503
3*400
87.9
15292
7856
95.7
18662
11226
99.0
21809
14373
8.7/10kV (15kV) Aluminum Conductor XLPE Insulated Underground Medium Voltage Power Cable
Introduction
This cable is used to transmit power on the power transmission and distribution line of A.C.50Hz, rated voltage 35kV or lower. In comparison with PVC insulation cable, it boasts not only excellent electric character, mechanical character, heat and aging-resistant character, environmental stress-resistant character and chemical corrosion- resistant character, but simple structure, light weight, no restriction by laying drop, and high temperature allowance for long-term working as well.
Working conditions:
1)This maximum working temperature of the conductor is 90 0C;
During having a short (lasting less than 5 seconds) the maximum temperature of the cable conductor shall not be above 250 0C; Environment temperature should be no lower than 00C for laying the cable;
2)Bending radius allowance of the cable:
Single core cable: No steel tape cable 20D; Steel tape cable 15D
To be laid indoors, in tunnel, cable furrow or pipe, the cable couldn't bear mechanical force outside
YJY
YJLY
XLPE insulation PE sheath power cable
YJV22
YJLV22
XLPE insulation, steel tape armor, PVC sheath power cable
To be laid underground, the cable could bear certain mechanical force, but it couldn't bear great pulling force.
YJV23
YJLV23
XLPE insulation, steel tape armor, PE sheath power cable
YJV62
YJLV62
XLPE insulation, have no the magnetismsteel tape armor, PE sheath power cable
YJV32
YJLV32
XLPE insulation, thin steel-wire armor, PVC sheath power cable
Be applicable to the well, water inside and fall in the bad soil, the cable cans bear the equal dint outside the machine with pull the dint
.
YJV72
YJLV72
XLPE insulation, have no the magnetism thick steel-wire armor, PVC sheath power cable
YJV42
YJLV42
XLPE insulation, thick steel-wire armor, PVC sheath power cable
Be applicable to the well, underwater with the bottom of sea, the cable cans bear the bigger pressure with lead to pull the dint.
Hint Specially
The single-core magnetism material packs the cable is not suitable for to use for the AC power supply back track, the necessity hour eligibility uses the single-core 62 or 72 type pack the cable.
Disallow the cent to cross the magnetism piping mutually when single-core cable establish, the in order to prevent results in the descent that cable transport electric current ability.
Test Voltage and biggest Discharge capacity of cable
Rated Voltage
(kV)
3.6/6
6/6
6/10
8.7/10
8.7/15
12/20
18/30
21/35
26/35
Test Voltage
(kV)
6.23
10.38
15.05
20.76
31.14
36.33
44.98
Discharge capacity
(pC)
10
10
10
10
10
10
10
AC voltage test of cable
Rated Voltage
kV
0.6/1
1.8/3
3.6/6
3.6/10
6/6
6/10
8.7/10
8.7/15
12/20
18/30
21/35
26/35
Test VoltagekV
3.5
6.5
12.5
21
30.5
42
63
73.5
91
min
Test Time
5
5
5
5
5
5
5
5
5
Max. DC resistance of cable conductor at 20℃
Rated cross area(mm2)
0.5
0.75
1.0
1.5
2.5
4
6
10
Cu(Ω/km)
Non tinned
36.0
24.5
18.1
12.1
7.41
4.61
3.08
1.83
Tinned
36.7
24.8
18.2
12.2
7.56
4.70
3.11
1.84
Al (Ω/km)
/
/
/
18.1
12.1
7.41
4.61
3.08
Rated cross area(mm2)
16
25
35
50
70
95
120
150
Cu (Ω/km)
Non tinned
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
Tinned
1.16
0.734
0.529
0.391
0.270
0.195
0.154
0.126
Al (Ω/km)
1.91
1.20
0.868
0.641
0.443
0.320
0.253
0.206
Rated cross area(mm2)
185
240
300
400
500
630
800
1000
Cu (Ω/km)
Non tinned
0.0991
0.0754
0.0601
0.0470
0.0366
0.0283
0.0221
0.0176
Tinned
0.100
0.0762
0.0607
0.0475
0.0369
0.0286
0.0224
0.0177
Al ( Ω/km)
0.164
0.125
0.100
0.0778
0.0605
0.0469
0.0367
0.0291
Structure of power cable
8.7/10(12)kV、8.7/15(17.5)kV 1-core XLPE insulation PVC sheath power cable
Nominal Area
mm2
Non armored
Tape-armored
Wire-armored
Reference diameter
mm
Approximate weight
kg/km
Reference diameter
mm
Approximate weight
kg/km
Reference diameter
mm
Approximate weight
kg/km
YJV
YJLV
YJV62
YJLV62
YJV72
YJLV72
1*25
23.1
775
620
25.0
1063
884
28.7
1662
1483
1*35
24.1
900
683
26.0
1204
960
29.8
1828
1584
1*50
25.4
1080
770
27.3
1406
1064
31.2
2063
1721
1*70
27.0
1314
880
29.0
1672
1200
33.0
2371
1900
1*95
28.7
1601
1012
31.4
1980
1348
35.5
2971
2338
1*120
30.2
1881
1137
32.8
2278
1486
37.0
3315
2523
1*150
31.9
2213
1283
34.4
2631
1647
38.7
3721
2737
1*185
33.6
2590
1444
36.0
3026
1820
40.4
4168
2962
1*240
36.0
3173
1686
38.3
3647
2092
42.8
4864
3309
1*300
38.3
3801
1942
40.6
4312
2378
45.3
5605
3671
1*400
41.8
4831
2353
44.9
5400
2835
49.9
7250
4685
1*500
45.2
5889
2790
48.2
6518
3298
53.4
8510
5290
8.7/10(12)kV、8.7/15(17.5)kV 3-core XLPE insulation PVC sheath power cable